    Hi, Sorry, I just realised it now. Currently Area A is set to arm at 'Instant'. That means all zones set to A will be instant. What I'm trying to achieve is on full alarm I want a timer to allow me to exit and enter with timer via the front door. (this is Entry/Exit - correct? and currently...
  2. A

    RKP addressing, 8XP-W adding

    Sorry about all the pictures. I dont mind the confirmation tone for part arm, thats fine. Area Options - Part Arm Instant and Part Arm Silent is ok? I guess if i chose Front Door contact as part of Area A then that would mean that upon full alarm, it would instantly arm and also be silent? I...
  3. A

    RKP addressing, 8XP-W adding

    . space . *ATTACH=full]85315[/ATTACH] *ATTACH=full]85315[/ATTACH] *ATTACH=full]85316[/ATTACH] <Moderators note> I have unattached the duplicates
  4. A

    RKP addressing, 8XP-W adding

    I have a scenario if someone can point me on how to set it. I wanted full alarm set to be only 10sec for exit before being set. I wanted part arm to be set so that it is automatically silent arm using quick set. I know how to do quick set on keypads. But how can I make it so that if i press '1...
  5. A

    RKP addressing, 8XP-W adding

    @Europlex lol. I find the continuous beep to be something wrong. I guess it depends on what the beeping is for. When a timer is set you expect beep beep beep like a countdown timer. Whereas a beeeeeeeeeeeep means something's jammed and you need to stop it somehow. Each to their own eh? So back...
  6. A

    RKP addressing, 8XP-W adding

    Hi, so I have tested voltage and its 12.71v between the power. So voltage not an issue. The PROX symbol is on the keypad. Do I need to unassign the tags and start again? Also, does anyone know how to change the exit tone when arming? Its a continuous beep. Would have preferred a beep beep beep...
  7. A

    CCTV recommendation needed

    Thanks for the reply sparkymarka, It will most likely be a TVI camera. I thought the purpose of the Spot out on the DVR was to be able to connect directly to a monitor and specify that spot camera to an existing one out of the 12. Or have i misunderstood the Spot out connection? Regards,
  8. A

    CCTV recommendation needed

    Hi, I have been asked to look for a CCTV system that fits the current criteria: Current situation - a factory that has an old system (8ch dvr) with 8 low quality cameras. Wired using BNC. His requirements - a 16ch dvr. He wants to keep his own cameras and add another 4 more. He wants to...
  9. A

    RKP addressing, 8XP-W adding

    Just another point to add, I remember at one point when I presented the tag to the 2nd RKP, it did make a beep as though it acknowledged it but did not say anything on the keypad. Now it doesn't even do that.
  10. A

    RKP addressing, 8XP-W adding

    1. Yes, has the prox symbol 2. I will have to find out later 3. I will have to find out later 4. Address 2 Thanks.
  11. A

    RKP addressing, 8XP-W adding

    Hmmmm, it doesn't on the second keypad and does work on the first keypad. Maybe faulty RKP.
  12. A

    RKP addressing, 8XP-W adding

    OK that part will be fine. I am trying to configure the tag to work on the 2nd RKP and this is what i am doing: setup users - user 002 (already using tag1) - press yes to everything - add tag? - Import - hold tag against the RKP..............nothing, no noise no beep nothing. Is that step...
  13. A

    RKP addressing, 8XP-W adding

    Hi, I have now managed to learn all the devices to the wireless expander. Thanks SecureIam. I have found the fault with RKP 2 was indeed one of the wires were wrong. So thats working. I wanted to add two smartkeys and 2 fobs to one user but does not allow me to do so. I can do one smartkey but...
  14. A

    RKP addressing, 8XP-W adding

    Brilliant, I will try that and report back. I didn't know about the A and B areas being on one zone not allowed. Is it correct the wiring method for the wireless detectors should be on WD Monitor? Regards,
  15. A

    RKP addressing, 8XP-W adding

    Hi, An update: So, i changed the address of the 8xp-w to 2. But before i did that i did a factory reset as the engineer password was not being accepted for some reason (said something about user code access or whatever). Anyway, here are the issues now: 1) expander can now be seen starting...