  1. acer54

    Baxi 105 HE Domestic Hot Water Problem

    Yes but the restriction was at the diverter valve inlet flange, the diverter valve was changed twice but the restriction was not easily seen if the pipe was left in situ, only when the pipe was removed for full inspection was the partial blockage seen - all the parts that have been changed +...
  2. acer54

    Baxi 105 HE Domestic Hot Water Problem

    Solved!!! Baxi engineer fixed the boiler last night, 22mm pipe from heat exchanger outlet to diverter valve inlet was partially blocked with black crud - new one fitted and hey presto everything working as it should! He said he could hear a small amount of "Kettling" which led him to suspect...
  3. acer54

    Baxi 105 HE Domestic Hot Water Problem

    Update. A joint British Gas & Baxi engineers visit has been setup - I hope this finally puts the DHW problem to bed!
  4. acer54

    Baxi 105 HE Domestic Hot Water Problem

    Is that the inline mesh cylinder filter on the right hand side as you look at the boiler? If yes then that has been checked and was clean.
  5. acer54

    Baxi 105 HE Domestic Hot Water Problem

    British Gas coming tomorrow morning - if no joy then will request Baxi engineer to try and put this to bed once and for all.
  6. acer54

    Baxi 105 HE Domestic Hot Water Problem

    I'm on a repair contract with British Gas, they paid for all the parts and labour, the probable down side is my monthly payment will probably increase when I renew the contract next year.
  7. acer54

    Baxi 105 HE Domestic Hot Water Problem

    I agree but surely it is fixable which why I ask the question on this forum.
  8. acer54

    Baxi 105 HE Domestic Hot Water Problem

    The Venturi has been changed to a new one The water flow is good I'm on a repair contract with British Gas, they changed all the parts.
  9. acer54

    Baxi 105 HE Domestic Hot Water Problem

    Recently my boiler is giving error code 60 when DHW is being used (fault on pump or low pressure). Pressure in the system when cold is 1.0 bar. When CH is on DHW works as it should everytime, the diverter valve spindle which makes contact with the pump proving micro switch in CH mode moves very...