Recent content by Ajitsinh

  1. A

    Biasi problem - Garda HE M96.24SM/B

    Yes. Agree with you. I have informed the agency who will arrange the enginner to visit sometime this (guy is on leave for last few days). 1. Water pressure is settled to 2.6 bar now. Not sure how we can reduce it to 1. 2. Fronst protection - it seems it kick off during winter when the...
  2. A

    Biasi problem - Garda HE M96.24SM/B

    1. DHW: Its working perfectly fine now as everytime as start hot water tap, boiler fires up and tap provide the hot water. 2. CH: All the radiators in the house start heating when Thermostat is 24. So OK. But yes something is wrong related to lights. As you rightly said, when we set Room...
  3. A

    Biasi problem - Garda HE M96.24SM/B

    Hi Terry Looks like the problem is solved now. Thanks for your precious time and the suggestion. Here is what I did: I switched off the electric supply. Set both DH & CH dial to 2. Room Thermostat to 24. Mode - Auto position. After 10 minutes started the power supply. First 1 minute - only CH...
  4. A

    Biasi problem - Garda HE M96.24SM/B

    Thanks Terry for your quick response. Just run the CH.... 1st & 2nd light flashing simultaneously (Frost Proect operation)....for 7-8 minutes. The moment temperature reached 60 degree (from 30), the boiler cut off. Same as above - 2nd and 3rd light flashing (Faulty mode). Now the temperature is...
  5. A

    Biasi problem - Garda HE M96.24SM/B

    Because of summer, C heating is off as no ON & FF time is set and boilder is set to Auto mode....let me set it to Manul mode and see the behaviour...will confirm you soon
  6. A

    Biasi problem - Garda HE M96.24SM/B

    I edited the above probelm description providing light combination & their menaining. Pls help if you can.
  7. A

    Biasi problem - Garda HE M96.24SM/B

    Hi, I have Baisi boiler model Garda HE M96.24SM/B. Its not working properly for Hot water. Room Thermostat: Set to 22 degree. DHW control knob: Set to 5 Ch control knob: Set to 6 Hot water will come for few minutes (may be a bucket or two). During this time, 1st and 3rd lamp flashes...
Back
Top