Recent content by Artisan Bathrooms

  1. A

    Vaillant combi heating coming on at random...

    Cheers for that Dave. Could the HW pre-heat properly warm the place up through a passing DV? It doesn't just come on for a bit - her flat was apparently at 18 degrees this lunchtime. Pete
  2. A

    Vaillant combi heating coming on at random...

    Hi Gents, I'm after a bit of advice about a misbehaving boiler if poss. Customer has a Vaillant turbomax combi about 3-4 years old. Works fine, but heating sometimes comes on at random in the middle of the day or early hours of the morning when it's not supposed to. She's had a new programmer...
  3. A

    dodgy conversion of old boiler to sealed system...

    ok - thanks guys. I've spoken to them earlier and already told them that best option is to replace this ancient lump for a shiny new one so hopefully we won't have to worry about it. Cheers gents...
  4. A

    dodgy conversion of old boiler to sealed system...

    Hi guys, I've been to look at a job for the replacement of an old (direct) megaflow with a new indirect unvented cylinder. The existing installation is appalling - no inlet control gear, no tundish on discharge etc, etc and the heating side isn't much better. With such a bodgy installation...
  5. A

    Black plastic supply pipes from cws...?

    I did have a look and couldn't find anything on the pipe. There was an awful lot of crap in the way though so I could've missed it...
  6. A

    Black plastic supply pipes from cws...?

    Thanks holty - sounds like the stuff. I've used the plasson fittings on blue MDPE but not this black stuff. At the moment the joints are made with pretty standard looking brass compression fittings. Are the c & d converters reducing sets to use old imperial pipe in metric fittings? and will...
  7. A

    Black plastic supply pipes from cws...?

    Hi guys, Got a situation with hot from a combi and tank fed cold so the customer wants the tank bypassed and cold hooked up to the mains. I come across this more often than I'd hope, but this case is a little unusual. Firstly, massive asbestos tank, so no cutting that up (or even moving...
  8. A

    Shower Pumps

    could be that the wiring diagram is just indicating the need for electrical isolation of the pump for servicing etc. having said that I don't know what pump you've got... eh..? negative head pumps I use operate via integral pressure switches..
  9. A

    vented cylinder vent pipe capped... advice..?

    Ok - thanks for that guys. You've pretty much told me what I thought anyway. I've certainly never seen this done before... They've had a loft conversion and presumably the builder found it easier to just cap the vent pipe than re-route all the pipework. The customer told me that "he wasn't...
  10. A

    vented cylinder vent pipe capped... advice..?

    Hi guys, Been to see something I've not come across before. Have to replace a whole house pump for hot and cold water 'cos the old one's broken and it needs to be a negative head anyway. Cold feed to pump comes from cws in loft space and hot from cylinder. The hot comes straight out from the...
  11. A

    drilling wall tiles

    I drill through tiles all the time - it's real easy unless they're porcelain. If they're porcelain you'll wish they weren't - you'll have to use a tile bit or one of those diamond grit mini core cutters if you need anything over about 8mm. Drilling porcelain should be done wet or your bits won't...
  12. A

    cast iron soil pipe renewal

    Well it certainly would look the part... I'm not too sure I'd want to advise it to someone who's not worked with CI soil before though.
  13. A

    cast iron soil pipe renewal

    Just find your nearest decent plumber's merchant and they'll have it (or get it for you). You're really better off with a fernco though...
  14. A

    cast iron soil pipe renewal

    You can get space saving bends on soil - look around. I'd rather use fernco type couplings if I were you - they're the rubber collar type with a big jubilee clip at each end. Id also rather just use one at the lower joint and then remake the whole upper part of the stack in plastic. It will...
  15. A

    Mixer shower

    Yes - flow limiters... Generally people want as much out of their shower as they can get though.