Recent content by Bayardmm

  1. B

    Do in-line extractor fans require maintenance?

    I used a vacuum cleaner nozzle on our inlet side and dislodged the trunking. I went into the loft to refit it and was amazed at how much dirt had accumulated on the fan blades. Used a small brush to clean it and its efficiency improved considerably. You could see steam being drawn into the inlet.
  2. B

    Gas fire ignition problem

    We have a Logik HE balanced flue gas fire which has recently become awkward to ignite. If I try to light the pilot, using the prescribed method, nothing happens. However, as I move the lever towards the high flame position, the fire suddenly lights, quite dramatically. The fire was serviced...
  3. B

    Baxi combi slow to fire up

    No Opentherm, and the heating has been fine, and still is as far as I’m concerned. It was just witnessing this, hopefully, isolated series of events that got me thinking.
  4. B

    Baxi combi slow to fire up

    we have a Baxi combi 800 boiler, 1.5 yrs old, and I have the heating flow temp set to 65 degrees. Today I just happened to be beside the boiler which had been sitting idle most of the afternoon due to unusual warm weather. I noticed that the water temp indicator displayed 26 degrees, and the...
  5. B

    Electric shower problem

    I have an electric shower which has suddenly stopped heating the water. I have checked everything, that I can, inside the unit and get all the continuity’s and resistances that I would expect. I get 240v when the pull cord isolation switch is on. Obviously, I cannot check the supply on load...
  6. B

    Mira electric shower problem

    Problem solved. New selector switch delivered and fitted, lovely hot water now. Great outcome, only £43 spent plus massive boost of self satisfaction.
  7. B

    Mira electric shower problem

    Yes I’ve got 240v. Is there a way to troubleshoot the selector switch. I have ordered one anyway as I can’t find a fault elsewhere. Failing that it’ll be a replacement, but finding one with a similar footprint may be difficult. I’ve noticed the current Mira showers have fixing screws in...
  8. B

    Mira electric shower problem

    Both elements read 13.8 ohms
  9. B

    Mira electric shower problem

    I ran it for quite a while this morning but didn’t notice anything untoward, although I wasn’t concentrating. I’ll try again.
  10. B

    Mira electric shower problem

    we have a Mira Zest 8.5Kw shower which has developed a problem. I can switch the power supply on using a cord pulled switch, turn the shower on but only get cold water regardless of the temperature setting. I have checked the thermal switch and get continuity, and high resistances in the heating...
  11. B

    Scantronic 9450 control box very hot

    I took the battery out last night and the temperature dropped to warm. I’m going to get a new battery today.
  12. B

    Alarm control box hot

    Thank you Sparkymarka, have removed battery and will seek replacement tomorrow. Do I have to get the exact replacement, 2.1ah or would the 2.3ah suffice.
  13. B

    Alarm control box hot

    the control box on my scantronic 9450 alarm is very hot on the top surface, not too hot to touch but significantly hot. My wife is concerned that it may burst into flames. I could pull the fuse, to disable the box, but would need to delve inside to disconnect battery. Tomorrow I’ll arrange an...
  14. B

    Scantronic 9450 control box very hot

    The battery is at least 10yr old.
  15. B

    Scantronic 9450 control box very hot

    the control box on my scantronic 9450 alarm is very hot on the top surface, not too hot to touch but significantly hot. My wife is concerned that it may burst into flames. I could pull the fuse, to disable the box, but would need to delve inside to disconnect battery. Tomorrow I’ll arrange an...
Back