Recent content by beolight

  1. B

    adding room stat to system plumber says not a good idea

    thanks for replies everyone @D_Hailsham i didnt know what a boiler interlock was exactly i assumed the cylinder thermostat was one so googled is a cylinder stat an interlock and got some interesting articles this was most promising...
  2. B

    adding room stat to system plumber says not a good idea

    this http://www.heatingcontrolsonline.co.uk/honeywell-zone-installer-pack-p-216.html pricey isnt it :(
  3. B

    adding room stat to system plumber says not a good idea

    currently the system i have only allows control of hot water and heating via the boiler vokera 14se i can turn off the heating in the hot press by turning lever ideally i would like to be able to control heating on both floor levels but to do this plumber says entire system would need to...
  4. B

    trying to water softener to work need help with controls

    found this http://www.waterdial.co.uk/images/pdfs/instructions/Aquadial%20Microsoft%20Microsave%20Instructions.pdf page 4 explains controls clearly enough going through troubleshooting page 10 tonight does seem to indicate defective timer motor from cursory glance
  5. B

    trying to water softener to work need help with controls

    thanks for reply i will check transformer working tonight when i get back but i assume when i switch dial to start and the unit starts up that transformer is okay i cant see any markings on unit to indicate brand or model number the silver pins on the day control should they be pushed...
  6. B

    trying to water softener to work need help with controls

    the guy who installed it cant be contacted anyways unit is not working properly and does not automatically do backflush anymore the salt level in tank is same as it was 3 months ago if i manually switch control to start it will work last year i cleaned tank out and got rid of all the...
  7. Untitled

    Untitled

  8. Untitled

    Untitled

  9. plumbing stuff

    plumbing stuff

  10. B

    fitting a magnaclean

    just trying to figure out if this a DIY job or not in a sealed system where can it be fitted? i dont have the space to fit it under boiler can it be fitted in hot press and which pipe should it be attached to
  11. B

    Vokera 14e not firing

    i know post is old but as vokera was fairly standard fit in ireland in the 10 years i think it might help to reply anyways id imagine your system isnt mains fed but attic fed pressure will only be 0.5 bar also i guess no filling loop is fitted post a picture of pipework in...
  12. B

    Heating system queries

    did you get a third party programmer fitted
  13. B

    Heating Control Options

    how did you get on with this also have vokera that isnt mains fed and constantly cutting out, no filling loop attic fed will only give you 0.5 bar pressure probably why no gauge in hot press