Recent content by BigJ

  1. B

    Glowworm Compact 100e Leaking on RH Hydro Block

    Hi Gas2Air - just for further reference if you ever need the product code for the diaphragm its S801191 - sorted now, will still have to wait till Monday to order...
  2. B

    Glowworm Compact 100e Leaking on RH Hydro Block

    yes mate thats the one - cant seem to find the part no though - will try again now to locate new diaphragm otherwise to the merchants on Monday...cheers for that
  3. B

    Glowworm Compact 100e Leaking on RH Hydro Block

    As above - leaking on RH Hydro Block Assembly when hot water is turned on. Do they do a repair kit for the gasket or new assembly anywhere - cant seem to find one cheers BigJ
  4. B

    Urgent HELP!!! Jaguar 23kW combi boiler problems....

    One thing I did notice was there wasnt an earth connected to the fan - someone must have pulled this off before I will have to pull the fan out to test then - any other ideas
  5. B

    Urgent HELP!!! Jaguar 23kW combi boiler problems....

    gas is 20mbar....does that help
  6. B

    Urgent HELP!!! Jaguar 23kW combi boiler problems....

    Fed up now of racking my brains over this - so defeat admitted and Ive joined this forum...... Ok - heres the problem..... Jaguar 23kW combi boiler When boiler is turned on, firing sequence doesnt occur, the fan doesnt kick in etc etc / the same when the hot water is turned on...