    can't get hot water and heating to work again, please help!

    Well I'd just like to post an update. Since my last post I never managed to get the lower radiators on, in desperation I today turned off the boiler, reversed the CH pump and ran it for 5 mins. Returned the system back to normal, fired up the boiler and all the radiators now work! Just wanted to...
  2. B

    can't get hot water and heating to work again, please help!

    Well gents thanks very much for your help. I tried the fill from the drain (had to replace the cock first otherwise I'd have flooded the house with the old one) and then bled the air out of the system. I now have hot water and all upstairs radiators are working. I hope an attempt at balancing...
  3. B

    can't get hot water and heating to work again, please help!

    Brassedoff, there is no room thermostat, I think I have found the cold water feed, it connects just after the valve and feeds straight to the boiler, does that sound right? there is an identical one just before the valve too though, anyway I'm removing the valve to scratch around with a bit of...
  4. B

    can't get hot water and heating to work again, please help!

    Thanks brassedoff, it is behind plasterboard I think that pipe as is the vent pipe. but I can remove it I suppose.. the whole system fills fine from the header tank though so wouldn't that mean the pipe is clear? Sorry for not explaining myself properly, it bleeds air, then water
  5. B

    can't get hot water and heating to work again, please help!

    Murf: The system bleeds air at the highest point which is two valves above the hot water tank. This cold feed Tee that everyone mentions as a source of problems I don't actually know how to identify! brassedoff: The pump is working, its brand new, I had the same problem with the original pump...
  6. B

    can't get hot water and heating to work again, please help!

    Thanks for the input, I have bled the pump though and refilled the system several times. Maybe I am refilling and bleeding it wrong? just doing it the way I have always done it and it used to work out fine
  7. B

    can't get hot water and heating to work again, please help!

    Hi all, I am having problems in getting my system up and running again. I had to drain it and experienced problems refilling it, all of which I think I have solved. Water flows into the entire system from the header fine, all radiators bleed fine regardless of which radiator valve is open, so...