Recent content by bongobus

  1. B

    timber frame bottom plate fixing

    can someone help on this, whats the best way to fix a timber wall stud on a concrete lintel thats spanning 2.2m - one end of the concrete lintel keyed in house other end sat on inside skin wall at dpc level. don't really want to be drilling into the concrete lintel.
  2. B

    150mm dpc workaround

    hi folks, according to building regs the DPC should be 150mm higher than the outside ground level however i cannot achieve this due to garden patio height being 1 course bricks 80mm difference. Would a drainage channel running along the building be acceptable maintaining this 80mm dpc level ?
  3. B

    550 stub ?

    is this allowed - shouldnt the return on the right be 550mm as per the regs ? the rear is a flat roof single storey extension, the kitchen area would have originally had a single opening door, this is a 2 storey house with this being the back holding a first floor
  4. B

    create an opening in a brick wall

    is this allowed - shouldnt the return on the right be 550mm as per the regs ? the rear is a flat roof extension, the kitchen area would have originally had a single opening door, this is a 2 storey house with this being the back holding a first floor
  5. B

    Any one used the BRICKY TOOL?

    Think you need more than glasses pal fnt. pal nah not that f idiot more like, tell you what go learn how to collect trollys cause thats all that fits for yer ! TxxT oh almost forgot like to rip other work eh - well care to visit ? or you all trap son !!
  6. B

    Brick to Brick solution ?

    .
  7. B

    Brick to Brick solution ?

    Are we saying block bond the inside extension wall to this corner - trouble is the bed joints are not the same level
  8. B

    Brick to Brick solution ?

    .m
  9. B

    Brick to Brick solution ?

    Whats flittons ? and if its the normal brick in the denser celcon block whats the problem ? Cavity was cut out otherwise external would be bridged with internal ??, The out side blockwork was a more dense block for tile hanging on batterns and permission granted by neighbour ? cant see the...
  10. B

    Brick to Brick solution ?

    ?
  11. B

    Brick to Brick solution ?

    I want to build a return joining the inner wall on existing house tieing in some of the block I am propsing to leave the furfix and butt concrete block to it but as it will be the back side of the furfix whats the best method to tie the block to the new extension inner wall containing this...
  12. B

    lintel door opening

    Hi all- my first post ! I am wanting to break through into a new extension. My existing house has common london brick and a hardish breeze type of block. i want to create a 30 inch opening i was going to use prestressed concrete lintels but wondered what to sit them on either side in...
Back
Top