I have a Vokera linear series combi boiler and a Honey well CM67 programmable thermostat which I want to change as it is too complicated to use. I wish to change it for a simple 7 day clock. Is this a simple operation?
The connections to existing programmer are simply brown and blue, trouble is...
Hi to every one
Need to replace my clapped out Triton T80 shower. The power cable is 6mm and has a run of approx 9m from consumer unit running under floor boards. Question is, can I replace with a 9.5kw unit using existing cable?
Thanks in advance
Brian
Hi to all
I am altering the position of our worcester 26cdi xtra and though I am a gas plumber, this is the first time I have encountered a pre plumb manifold. I will of course renew the "o" rings for refitting the appliance, but is there anything I should be aware of whilst removal? it seems...
Yes, give em a call and ask them to "check pipe for safety" no charge for the service either. As previously stated, they would have done this when laying new pipe but better to make sure.
Brian (ex British Gas)
Worcester 9.24 Electronic combi, water pressure rising to 4bar when c/h is on only. With hot water only no pressure problem only water does not get hot enough for a wash! filling loop is turned off and not letting by. Heat exchanger problem?? also water switch?? This is a dinosaur of a boiler I...