Recent content by cocoa

  1. C

    Biasi M90e 24s - Boiler runs but no ignition spark

    Okay - fixed it. Found no power supply to the air pressure switch - no continuity through the wiring loom. Soldered three new terminals to the switch and okay. :lol:
  2. C

    Biasi M90e 24s - Boiler runs but no ignition spark

    Hi Tony, Forget the wife - she's logged off and gone to bed. The fan is running - boiler doesn't start. Turn the control switch to summer setting, turn the hot tap on - fan is running - boiler doesn't start. When the boiler worked okay. you would hear the boiler run when switched on and...
  3. C

    Biasi M90e 24s - Boiler runs but no ignition spark

    Sorry Tony - didn't realise the wife had logged on this evening with same question.
  4. C

    Biasi M90e 24s - Boiler runs but no ignition spark

    Hello, please can you help. My five year old Biasi Riva Compact M90e.24s started playing up the beginning of this week and now there is no ignition spark when starting. When the central heating was working normal, hot water was supplied at the tap, but with the central heating not in use, if you...