Recent content by Comedydave

  1. C

    Screws for Aquapanel Exterior

    Hi Knauf Aquapanel Exterior recommended screws are about £70 for a box of 250. I only have a small job and can't warrant paying that much and for an amount I don't need. I have these for a different job: "SPAX T-Star Plus Facade Screws Stainless Steel A2"...
  2. C

    Boundary solution help required

    Thanks. Fully agreed. Any suggestions on getting it reduced and keeping it reduced?
  3. C

    Boundary solution help required

    Ideally yes, and I'm sure he'd give it a go, but at the end of the day, damp in my kitchen is a me problem, not a him problem, and reliance on others' goodwill is something I'd rather avoid. He might be fine and diligent but I think a solid solution is probably best...
  4. C

    Boundary solution help required

    It's 100mm. So a low brick wall would be right up against the house and might be too tight - I can't see how to insert a DPM into that, joining with the DPM in the house wall... And it feels that if there were a tiny gap it's just asking for trouble with buildup of crud over the years. A low...
  5. C

    Boundary solution help required

    Hi all, As my diagram tries to show, we have a rear extension the wall of which is set back from the boundary with my neighbour by 100mm. This was because the neighbour didn't want to have founds on his land - which was absolutely fine, no issue. The level of the gardens rises as you move away...
  6. C

    Combi boiler fed by pump from tank

    Hi Madrab - thanks for this, appreciate you coming back. One question though: your point to "avoid if at all possible" - did you mean "avoid laying a vertical cylinder on its side" because (a) the drawoff would be 1/2 way down and (b) the heating water in the coil would now have to go in an "up...
  7. C

    Combi boiler fed by pump from tank

    Cheers @MeldrewsMate These are all very good points. Thanks for the idea on using the shower pump to rig up a boost input to the combi on the cold, then a balancing boost to the shower cold in.... I think it's probably a bit of a "hack" though, and liable to end up costing more to rip out. I...
  8. C

    Combi boiler fed by pump from tank

    Thanks for the responses chaps. The storage space would be the only advantage of the combi it seems - and so the question is do I really need it. @Madrab thanks for the info re whole house pump and limiting switch. Perhaps there is a third option - better placing the hot water cylinder to...
  9. C

    Combi boiler fed by pump from tank

    Hi TL;DR - I want to get a combi boiler to save space but want to increase the pressure of my water by pumping water from my tank through the combi I currently have a 2bar shower pump pumping cold from my tank and hot from my cylinder to my shower. Now we're getting the house renovated, and one...
  10. C

    Priming zinc plated plasterboard mushrooms

    Lovely job JohnD, thanks very much! I'll get me some of that Dulux Metal Preservative primer so.
  11. C

    Priming zinc plated plasterboard mushrooms

    Hi, I have attached my insulated plasterboard to the sloping part of the ceiling with zinc plated screws through 3cm metal discs (which I presume are zinc plated too but the bag they came in has nothing on it!) I have read a number of posts about rust showing through as emulsion has reacted...
  12. C

    Hardie Backer/knauf Aquapanel + insulating board

    Hey Chappers, thanks for the idea. I think your suggestion could indeed work and cut down on any problems with bringing the battens to the front. Cheers!
  13. C

    Hardie Backer/knauf Aquapanel + insulating board

    Hi I've googled extensively for this with no luck. I'm redoing the bathroom, with the bath/shower against the external (215 mm solid brick) wall. At the same time, I'm redoing the other external walls in the house with 60mm PIR backed plasterboard. I want the same thermal effect in the...
Back
Top