Recent content by dan21mag

  1. D

    gas pipe and combi cost

    about 1200 plus materials...
  2. D

    Baxi (2) Solo 50PF

    that raden is such a t*at... still lives at home with his mum and soldering iron..
  3. D

    Water main pipe size

    1/2 inch deffo, just put a new stopcock on 1 (internal bore), plasson fitting will surfice from any good plumbers merchant... (i had the flu last week) :)
  4. D

    Ideal HE24 Combi Boiler

    i had this problem a 2 months ago with an ideal isar combi, pump wasnt up to the job and id fully powerflushed it, ideal changed pump no problem since..... also had the error message on an icos 24he system, intermitent fault on pcb, have to reset to unlock the error, so far its only happened...
  5. D

    Who pays, installer or household insurance?

    fitting pops off after a month??? my 1st thought would b it probably had a helping hand(or foot) to pop off!!
  6. D

    Noisy Grundfos 15/50 Pump

    15 years, mmm gates might not shut off 100%, nuts could be siezed, approach with care, or call a plumber
  7. D

    Gas analyser readings

    installed a baxi recently, o.ooo6 mmmmmmmmmm
  8. D

    Part "p" an all that

    ill check nxt week wen bak on job, but pretty sure they r low voltage, being as only a data cable,,,
  9. D

    Powermax 155 pressure problem

    Theres a pump at the bottom of the powermax 155 i thinx... has those awful ball'o'fix (slotted) pump isolating valves .. they always leak... check too see, if so, change and cross fingers!!!
  10. D

    Hot water in taps but not in shower??

    looks like a trevi... does it say "t" on the chrome mixer .. or "thermostatic"????
  11. D

    Hot water in taps but not in shower??

    Is the shower thermostatic????
  12. D

    Part "p" an all that

    Cheers for that map... The Quartz pump processor in loft has a data cable from it to the shower control... is that classed as electrics??????
  13. D

    Part "p" an all that

    so........ is the legal way forward for me to leave the fuse conn' units in place and let the "p" sparky wire in the integral pumped power shower box on the wall in the bathroom???? Also other shower is aQuartz... so the processor and pump will be in the loft(not special area) so can i wire...
  14. D

    Part "p" an all that

    Puttin two power showers in a house im workin on.. Came off the immersion with a double spur... ( 2 fuse connection units).both rated at 3 amps( but 160 watt motors on both pumps) got grief from a jumped up sparky telling me i should be part p to spur off the immersion(ok) but he told me i...
  15. D

    Cast Iron Stack

    £220 for cash.. plus a lotta diesel to get to scotland :)