    Baxi Neta Tec Combi 28 GA Leak

    This is the part you need.. remove the motor and then remove the silver clip behind the motor and pull the diverter valve out and replace.. you might need to remove the pressure sensor to get the silver diverter valve clip off
  2. D

    What is the difference between OF, and BIO filters for boilers?

    I don't dabble with bio mass or oil but your question doesn't make a lot of sence.. Care to elaborate?
  3. D

    anyone had to replace a combi condense trap?

    All done thanks guys.. Worked fine when cleaned and dried.
  4. D

    Plastic pipe ID and stop cock advice.

    That's why I do.. Never had an issue
  5. D

    Plastic pipe ID and stop cock advice.

    It was an assumption on the photo you provided and mentioning there were no markings on the fitting (old hep2o fittings didn't have the brand printed on it either) also the metal insert and grab ring looks like the hep2o system.. I could well be wrong, But if your making alterations as long as...
  6. D

    Plastic pipe ID and stop cock advice.

    That's the old style hep2o pipe.. Doesn't matter what fittings you use on it as long as the inserts are the same make
  7. D

    End feed fitting slightly over heated

    Yes should be fine.. Just check that the solder runs ok
  8. D

    Bluetooth adapter

    That is the one I just bought to and it works great
  9. D

    anyone had to replace a combi condense trap?

    Already entered my details for that one.. Just waiting for the powers to be to activate it.. But I'm kind of thinking washing the trap out has made it wet so it needs time or a hair dryer to dry it out.. I'm going out tomorrow to check it over
  10. D

    NCS or AT Risk

    I would still list it as NCS on the cp12 just to cover yourself
  11. D

    anyone had to replace a combi condense trap?

    ok guys, I am a RGI, but my friend is'nt. was just trying to save myself a trip out there. i have just never come across the sensor in one go faulty before
  12. D

    anyone had to replace a combi condense trap?

    a friend of mine called me as his boiler is not working (main 24 he) seemed like a condense blockage so i talked him through cleaning the trap out which was filthy. now he says it works fine with the sensor wires disconnected but when he connects them it cuts out again (red light permanently on)...
  13. D

    Combustion chamber forum

    Ahh ok thanks.
  14. D

    Combustion chamber forum

    Hi guys, I have just entered my rgi info to get on to the combustion chamber forum. Is there a delay until it works.. When ever I click on combustion chamber it just shows me the page with the details I entered
  15. D

    baxi neta-tec fga results

    i did run it for a day beforehand.. maybe needs a week or so. only noticed today my analyser would not read 0.008 as the maximum cut off for boilers. without wanting to sound stupid i presume 0.0080 is the same reading? Ive never had a reading before that is'nt 0.000 someting Bloody zeros get...