  1. D

    Glow Worm Ultracom 38cxi central heating problem.

    It's a Combi - UltraCom 24cxi.
  2. D

    Help with my storage heater

    Yep! That should be your cheapest option. Running the fan (boost - I think) won't use a lot of peak rate electric, but over use might mean you run out of heat before your next load of night charge. Running the fan & the instant heat (combi - I think) will cost you a fair bit, although how much...
  3. D

    Help with my storage heater

    Hopefully someone with more knowledge than me will give you a full answer, but I'm guessing this unit has 2 connections to the mains supply. 1 foe the economy 7 and another for constant power. The combi & boost functions will utilise peak rate electric to either drive a fan to increase the...
  4. D

    Glow Worm Ultracom 38cxi central heating problem.

    Thanks Micky. Gave that a try as my total load is only about 9-10kw. Problem is when it first fires up it seems to still put out the full 18kw for the first 60 seconds (full flames shown on display). After 60 seconds it seems to drop down to the 10kw I've got it set at (max 2 flames) and the...
  5. D

    Glow Worm Ultracom 38cxi central heating problem.

    Hey Switchmode, Did you ever get to the bottom of this? I've got the same issue on the 24kw version of this boiler. Mine seems ok as lonng as I've got the CH set above 70, but below that I seem to have the same problem as you. Watching it fire up I can clearly see it's going to overshoot &...
  6. D

    How do you know if a pipe is imperial or metric?

    Thanks all! Will get an imperial fixing just incase it all goes wrong, but I'm 99% sure it's metric. Found a solder joint that I could access that looks to be on the same kind of discolored pipe with 15mm on it. Oh, and the other marking was >B< 864 (BS864) so all is well. Thanks for the...
  7. D

    How do you know if a pipe is imperial or metric?

    The house is 150yrs old, not sure how long there has been a bathroom, but the existing one was fitted in 1986 I think (hence it's time for a change!). I just don't know if it was a suite swap, or full re-plumb, the the pipework could be older. No sign of anything suggesting sizes on any...
  8. Untitled

    Untitled

  9. D

    How do you know if a pipe is imperial or metric?

    Thanks for the quick replies, forgot to mention it's 15mm / 1/2". I'll have another look for markings on the solder joints, not found any so far though.
  10. D

    How do you know if a pipe is imperial or metric?

    Hope someone can help me... I'm trying to T in to these 2 pipes using speedfit. Bit concerned as to the colour difference though. The top one is hot (from tank) and the bottom cold (mains). Is it just condensation, etc. that has caused this, or could it be an older, & therefore imperial pipe...
  11. Untitled

    Untitled

  12. Pipes

    Pipes

  13. D

    My new Bathroom

    Harsh! Looks good to me! You'll always find something you could have done better once you finish, but I'd be more that happy if that were my bathroom!
  14. D

    Tiling over plasterboard, should I join at ceiling level.

    I'm preparing a plasterboard wall to be tiled & tapeing all joins. Question is, do I jape the ceiling to walls? The tiles will cover the join, so is it better to leave the ceiling independent incase of movement? I've looked, but can't seem to find an answer to this. Thanks! - Sorry, just...
  15. D

    HepV0 Valve

    But it doesn't act as an air admitance valve...