    Candy CDI 45 won't stop filling

    Yes the cause the missing tray: When I put back the upper tray with the spraying arm attached the problem was solved.
  2. D

    Candy CDI 45 won't stop filling

    Hi! The symptom is: at the program start the draining is okay, then the inlet valve is also working, then the water level pressure sensor is also ok, but after that when the circulating pump starts to work maybe it creates a pressure wave but the pressure switch clicks again and so the inlet...
  3. D

    Ariston Diverter Valve Bug

    Hi! Just reporting to share the "happy end" as well: Yesterday I succeded to fix the problem finally. I had to add a few mm to the shaft and now it's working perfectly. I don't get it why it wasnt working with the brand new valve + motor combo but that's life. :-) Thanks and cheers!
  4. D

    Ariston Diverter Valve Bug

    At the end I replaced both the valve and the motor as well. I checked it outside before install them into the housing and they worked properly. Is there any other path then the diverter valve? This hole marked with red on the last image about the housing is normal? I have the user manual if...
  5. D

    Ariston Diverter Valve Bug

    Hi! I have an "Ariston Genus Premium 24" wall-hung condensing gas boiler. It's 4 years old and 95% perfect. A few months ago a leaking appeared to the diverter valve motor and some buzzing noise came from there. First I replaced the motor and the O-rings on the valve itself. Then it was not...