    I hope it is OK as my sink directly below the CU. Only showers or baths have special rules, as you're likely to be using them naked.
  • ericmark
    ericmark replied to the thread RCD tripping on a light circuit.
    A RCBO supplies one circuit, when it trips we are 95% sure it is that circuit, note the yellow test button, it may be twin or single...
    • PartID_CU.jpg
    • Diffrence line neutral 8 Feb 24 reduced.jpg
    • VC60B.jpg
    • RCD tester ramp.jpg
  • ericmark
    FCU one hopes will have a double pole switch, but the line can be locked off by putting a lock through the fuse carrier. Lights switches...
    • 1769901781828.png
    • 1769901938149.png
  • ericmark
    ericmark replied to the thread Electric boiler?.
    Had the heating worked reasonably when we moved in, then likely I would have done nothing. However, it was a complete mess, and my...
    • 1769900953831.png
  • ericmark
    ericmark reacted to JohnW2's post in the thread Electric boiler? with Like Like.
    In 1978, I was living in a house which had no central heating of any sort ! You have spent a considerable amount of money in order to...
  • ericmark
    ericmark reacted to Harry Bloomfield's post in the thread Electric boiler? with Like Like.
    I would suggest most people with any sense, invest heavily for their comfort, in their older years. As I did. This house had no central...
  • ericmark
    ericmark replied to the thread Electric boiler?.
    Down to age, I was in a house with gas hot air central heating, and floor to ceiling picture windows in the 1978 winter of discontent...
    • 1769884120194.png
    • 1769884402480.png
  • ericmark
    ericmark replied to the thread Electric boiler?.
    My oil boiler will continue to run, until my batteries go flat, and the solar could mean they could last for weeks. I also have one open...
    • Back-up-power.jpg
    • 1769877293835.png
    • 1769877448802.png
  • ericmark
    ericmark replied to the thread New RCD needed - probable cost..
    Should give you an idea what they look like and cost, I went for around the cheapest I could find. Again the whole unit, with surge...
    • 1769874574941.png
    • 1769874849743.png
    • 1769874668256.png
    • 1769874622241.png
    • PartID_CU.jpg
  • ericmark
    I did wonder if the way to go is an inverter generator. At 3 kW it would run all garden tools, the largest is the leaf blower at 3 kW. I...
    • 1769869751955.png
  • ericmark
    ericmark replied to the thread Electric boiler?.
    I have a multi-fuel option for DHW, suppose no reason not to also have a multi-fuel option for CH. As long as both heat the water to...
  • ericmark
    That's an expensive grinder, is it gold-plated? I keep finding the odd job when I need a grinder, but not enough to pay out that much, I...
    • 1769866110631.png
  • ericmark
    ericmark replied to the thread New RCD needed - probable cost..
    How far you go is up to you. In the 90s my son became a radio ham at 14, and I decided all should be RCD protected to protect him. My...
  • ericmark
    Switch back box used as junction box in your case.
  • ericmark
    The standard British wiring uses the ceiling rose as a junction box, so when it is replaced with down lights, we should have a junction...
    • 1769856914496.png