    ericmark reacted to ebee's post in the thread Is it just me with Thanks Thanks.
    Nice one Eric :giggle:
  • ericmark
    I don't know about you, but my car will not transport large stuff. I used to have a Renault Kango mobility car not much bigger to the...
  • ericmark
    ericmark replied to the thread Is it just me.
    At school, three of us were interested in electronics, we were asked by an old lady to repair her radio, she did not like the new...
  • ericmark
    ericmark replied to the thread RCD Type for UV Pond Filter.
    There are 10 mA RCD sockets, but these are often a silly price. I have three outdoor sockets, two on their own RCBO, and one on a shared...
  • ericmark
    I just answered a post, and saw posts listed below it, and nearly clicked on them. It is so easy to miss the dates. Can anything be...
    • 1777892133956.png
  • ericmark
    Oh, it does sound like my house when I moved in. I have a C Plan, no question, it is a C Plan, but two pumps and two motorised valves...
    • C-Plan_old2.jpg
    • C-Plan_old.jpg
    • C-Plan.jpg
  • ericmark
    I know we often called it PAT testing, however as far back as I can remember it was called the inspection and testing of in-service...
  • ericmark
    ericmark reacted to flameport's post in the thread Low resistance on microwave oven with Like Like.
    Insulation resistance testing for circuits is done with all loads disconnected, because if loads are connected, faulty results will be...
  • ericmark
    ericmark reacted to JohnW2's post in the thread Bathroom fan switch with Like Like.
    I think that the suggestion (as proposed/discussed by BAS in the distant past) is that a DP switch would allow both light and fan to be...
  • ericmark
    ericmark replied to the thread Replace T40 honeywell by Hive.
    The old thermostat did not NEED a neutral, they would work often better with one, but will also work without one, it would also switch...
  • ericmark
    ericmark replied to the thread Bathroom fan switch.
    Yes, I was reading the Approved Document not the law, which said if you have windows which did not open, then you must be able to use...
  • ericmark
    ericmark reacted to jj4091's post in the thread Bathroom fan switch with Thanks Thanks.
    Apparently one of the part F building regs mandates that a room with no opening window has to have a method of forced mechanical...
  • ericmark
    ericmark replied to the thread Bathroom fan switch.
    I think there is a laid down time. But there is nothing to say must be linked to lights, so a simple pneumatic time switch is all that...
  • ericmark
    ericmark replied to the thread Bathroom fan switch.
    Were you around in Ban-all-sheds days, I remember him detailing how to wire up a bathroom fan with a double pole light switch and a...
  • ericmark
    ericmark replied to the thread Bathroom fan switch.
    Seems an error in the wiring, but I don't know Irish rules. Years ago before low energy lighting the rules in the UK were that the fan...