Recent content by frenchie1

  1. F

    CONFUSED

    basic requirements for a combi boiler trv's on all rads except ones with a room stat in,boiler interlock,auto by-pass if not fitted to the boiler & a time switch best practice as above but with programmable room stat 8)
  2. F

    replacing old boile with condensing vaillant ecomax

    basic requirements for a combi boiler ( condensing ) trv's on all rads, except in rooms with a room stat,boiler interlock, auto by-pass if not fitted in boilr & a time switch, best practice........all above except change the room stat for a programmable room stat 8)
  3. F

    Fixing Baths

    theres usually 2 L shaped brackets that come with a bath, srew 2 the wall & then underneath the bath on to the wooden frame, if not any diy store will sell them 8)
  4. F

    Plumbing in a new utility room - some newbie questions!

    depends on the waste on your sink 4 the waste size, sink 40mm, whb 32mm. pipe in2 the soil stack using a pipeboss is ok no solvent needed only on solvent cement wastepipe, 2 get a water tight connection in ur piping boss u get a rubber that fits in2 it you can hire a core drill 4 which eva...
  5. F

    Thorn EMI Apollo

    sounds like the thermocoupling again or even the gas valve 8)
  6. F

    Scaled up DHW Heat Exchangers

    take it off n soak it in a mild acidic solution, get a anti scale device fitted as well 8)
  7. F

    ferroli combi 77 ff. gc 4726704. 1990

    thanx slugbabydotcom, very usefull.... cheers m8. 8 just foned insurance & ur all rite, not covered as not a breakdown 8) )
  8. F

    ferroli combi 77 ff. gc 4726704. 1990

    client has requesed it be done ( insurance will pay ) 8)
  9. F

    ferroli combi 77 ff. gc 4726704. 1990

    im corgi registered chris,, just lacking experience as not long qualified, came on here for help as i thought more experienced guys would help , but obviously i was wrong 8)
  10. F

    ferroli combi 77 ff. gc 4726704. 1990

    new ignition device? which contains ? ignition transformer? 8)
  11. F

    ferroli combi 77 ff. gc 4726704. 1990

    pilot will light if lit with a match, thermo coupling ok. problem is it will not light automatically wen ignition button is pressed, everything else working fine just the little problem of the ignition, any ideas plzzzzzz 8)
  12. F

    Push-fit fittings

    ive just done a job at the mailbox, a big complex in brum consisting of 190 odd apartments, starting prices at £190 k where all the water connections are in copper pushfit, including mains water, unvented & all heating systems, all works carried out by a big building firm 8)
  13. F

    ferroli modena

    yes there reversable flow & tried turning down the lockshields still the same 8)
  14. F

    ferroli modena

    recently installed a modena & 6 rads & a towel rail all rads av trv#s on & towel rail as 2 off lockshields on, but just lately ive noticed that 2 ov the trv#s are makeing noises like theyre 1/2 open ( jumping spindles ) even with the heads off this noise still occurs any ideas...
  15. F

    Inefficient Combi

    sounds like the overheat stat 2 me which ferroli? 8)