    Sime 30BF boiler issue - No hot water unless central heating is also on

    Thanks for your help all issue is now resolved... the hot water was not working because the Divertor Valve Microswitch was not mounted properly on the end of the divertor valve. Long journey but learned a lot about combi-boilers along the way
  2. G

    Sime 30BF boiler issue - No hot water unless central heating is also on

    Hi many thanks for your reply I haven't rewired as such just replaced the PCB and the connectors only go in a certain way on the PCB so I am confident that these cannot be mixed up. Also did a continuity test of the wiring. The replacement of the PCB cured the ignition problem and got the CH...
  3. G

    Sime 30BF boiler issue - No hot water unless central heating is also on

    Hi apologies if I am repeating other posts was wondering if I could please ask for some help for my boiler at my holiday home in Cyprus. Our Sime 30BF boiler was not igniting and finally managed to get it up and running by replacing the PCB. This is the 2nd PCB I replaced in 1 year to get it...