Recent content by garyf

  1. G

    BOSCH MAXX Dishwasher, Bottom Tray Not Clean

    Hi, I have a BOSCH MAXX Dishwasher SGS45E08GB/45 TYPE S9G1B. The dishes in the bottom tray are not getting completely clean. I have checked the drain outlet as per advice on previous threads, I did get some crud out from under the small panel in the bottom of the filter housing, and also...
  2. G

    Bosch WFL2260 Wash Machine Brush Replacement

    Thanks sleepyhead. Anyway I can tell by machine serial number or similar what motor may be fitted? The bushes I have ordered are just a pair of carbon pieces on what look like coiled springs. They are shown on the Bosch site as applicable to my machine (WFL2260/01UK)
  3. G

    Bosch WFL2260 Wash Machine Brush Replacement

    Our Bosch WFL2260 has given up the ghost. It was working but making a ticking noise when spinning. Now it does nothing, apart from fill up with water. Drum doesn't turn at all. having read this forum and another one, I've decided to have a go at replacing the motor carbon brushes. Spares are on...
  4. G

    Boiler runs continuously even when programmer set to OFF

    Went into th eloft yesterday to recalib the stat. It had manged to recal itself to some extent, with the 'click' coming at around 15 deg C. I took off the dial and moved it around as suggsted. Click then coming at about 25 deg. Thermometer on my mobile phone said 27 deg, so near enough for me...
  5. G

    Boiler runs continuously even when programmer set to OFF

    3 port valve. I'll give the recalib a go too
  6. G

    Boiler runs continuously even when programmer set to OFF

    Thanks Simon. On further examination, problem only seems to happen late at night / early morning, when at coldest part of day? Took a look at frost stat, after taking cover off, its got graduated scales with numbers 5, 10, 15, 20. Number 5 was at the top, indicating the set point of 5 deg C? I...
  7. G

    Boiler runs continuously even when programmer set to OFF

    This has just started happening with no explanation. Potterton E50? boiler, fully pumped system. DHW tank and pump in loft with frost stat. The boiler is running and rads warming up even when programmer is set to OFF. Only way to stop it is turn off boiler. With programmer at OFF on both HW and...