  1. G

    Hot Water Tank - Immersion Heater Thread No Hole

    Evening All, Just looking at installing an immersion heater in to the top of my tank, only to discover the thread is there for one, but it seems to be sealed, did think it would be some sort of cap, but seems pretty solid bit of copper, Tank is probably well over 20 years old, guessing it just...
  2. G

    Euramo Gold Body with Grundfos head

    Guys, My Euramo Gold Pump speed switch melted last night, I have just ordered a grundfos alpha2 to replace, for the time being my dad has loaned me a grundfos 15-50, will the grundfos head fit the euramo body for the time being. Cheers Gaz
  3. G

    LED Downlights

    That may be part of the problem, I may have dribbled too much and shorted the wiring.
  4. G

    LED Downlights

    Chri5 - The varilight dimmer that I used work to a min of 10w, one of the circuits on the double switch works fine, same bulbs same switch, the other side comes on and then trips, surely if the dimmer was not suitably rated the other working circuit would have a problem ? this one works and dims...
  5. G

    LED Downlights

    Average size living room, lights were already installed when the guy brought the house, a slight over kill for the room size, he just wanted LED replacements. Going to test with halogen bulbs back in and a normal switch and see what happens as a process of elimination. Gaz
  6. G

    LED Downlights

    I changed the whole fitting, new ones have a blue quick release clip on them. The circuit was in three parts before - left it the same, basically just swapped over fittings, lights and switches. As for the min load, it is 10 watt, bulbs are 5 each, 5 on each circuit so should be okay there, it...
  7. G

    LED Downlights

    They are 240 volt.
  8. G

    LED Downlights

    I have just finished swapping over 15 halogen downlights for dimmable led alternatives, they are in a living room, the 15 lights have been separated into three circuits, each with five downights on, and each controlled by a dimmer switch, one of the circuits works fine, but the other two stay on...
  9. G

    Designer Radiator (Part 2)

    Guys, I posted a month or two back about my tall venezia radiator not getting warm at the top, which we solved thanks to the help on here, but at the time I never noticed that only the first four upright parts were getting warm these are the closest to the inlet side, the last four don't seem...
  10. G

    Tall Designer Rad.

    Turned off all the rads except the new one, as mentioned by chr15, and this worked the rad started to warm up at the top, obviously it will take longer with the rest of the system open. Cheers Gaz
  11. G

    Tall Designer Rad.

    It's an open vented system, will shut off all the other rads tonight and see what that does. Gaz.
  12. G

    Tall Designer Rad.

    Yep, water did eventually come out, but if you close the valve, and then reopen a minute later, a little more air comes out, not much though, did this about four to five times. Gaz.
  13. G

    Tall Designer Rad.

    It was just a red round circle, no writing, and no mention of it in the destructions. Gaz.
  14. G

    Tall Designer Rad.

    Wonder if you could help us out, just fitted one of these tall designer rads, fitted the bleed nut and stopper at the top and plumbed in the bottom as usual, opened the valves, bled the air, but after 15 to 20 mins it was still cold at the top, and just warm around quarter of the way up, after...