I want to fit a wall hung toilet and would like to use a no touch sensor flush such as.... http://www.roperrhodes.co.uk/product/contactless-dual-flush-sensor
Most of the frame based cisterns include press button flush please which also double up as access points. Like this...
Just taken a look at the sensor - there is a tab/clip which holds the electrical connector in place. The tab appears to have broken off and the connection was therefore loose. Pushed connector on firmly and appears to be ok. I guess I might need a new sensor fitted to renew the clip and secure...
Ahhh, caught it at it this time.....
Got an e28 error. Dhw light was on but ignition light not on....... Turned tap off and tried again it came on fine again......
Ideas?
Boiler is about 5 years old. All fine until a couple of months ago...
Sometimes when taking a shower (Mira mixer) there is no hot water when shower is first put on. If left for a minute of two it will then come hot (this is MUCH longer than usual). Also sometimes during a shower the water...
By way of a further question...
The manual states that if the system temp goes below 5C frost protection is trigged and boiler fires on its lowest setting until thr system temp reaches 30C.
Am I right in assuming its the CH water temp sensor that is used to monitor this or is the DHW temp...
Hi
I have one of the above which is now about 3-4 years old. It is located in our garage.
When still under warranty a couple of year ago we had two occasions on very cold nights where the boiler froze.
We awoke to no heating/HW and the boiler displaying a low pressure warning E119. The...
Ahhh that's interesting - thanks. I was following what I thought was pretty general practice that 1 bar cold was what to aim for but happy to be corrected. My experience suggests this mean that when hot the system will be running at about 3 bar which is into the 'red' on the gauge. (boiler...
Yes - I had wondered about that - I can see it being on all night and never warming the garage enough to kick the frost stat off - pipe stat sounds more what I need.
ok - thanks. The pipework around it boiler is lagged and not had any probs with that ever freezing - yet...!
For the poster below - the boiler info does say it has internal frost protection....
I have a Baxi Duo Tec 33HE, 18 months old and mounted in our garage.
Twice in the past week I've woken up to a cold house (!) an error code 119 (low system pressure).
On investigation, the system pressure gauge read about 1 bar (as expected) but the I still couldn't reset the system as...