    Vokera Boiler Linea 28

    Hi My Vokera Linea 28 has just recently started constantly 'switching' the flame on and off at around 5 second intervals when in central heating mode. The pump continues to run. If I switch it all off for around 10 minutes, it is fine then starts 'switching' again after a couple of hours of...
  2. G

    Vokera Linea 24 CH Problem

    I think I know where you are coming from, the same happened to my Vokera boiler, it's the shaft on the control knob that snaps. Turn this control, if the lights do not go out in the off position it's the shaft that is broken. A new knob is around £6.00, you need to be a little mechanically...
  3. G

    Some Advice please before I call a Plumber?

    Got new switch...£6.50 for a 20p piece of plastic!!!! Fitted and working, thanks again for all your help! :D :) :D :) :D :) :D :) :D :) :D :) :D :) :D :) :D :) :D :) :wink:
  4. G

    Some Advice please before I call a Plumber?

    Thanks again for everyone's help and suggestions, I'll order a new part tomorrow I got it to run for a few seconds after turning the broken shaft but then it stopped, I suspect the switch disconnected as there was no shaft in there to keep it on. Needless to say, I isolated the appliance...
  5. G

    Some Advice please before I call a Plumber?

    Worked out how to set it for heating and water by turning the broken stump on the pcb. Thanks for the advice!
  6. G

    Some Advice please before I call a Plumber?

    Arggghhhh: just re read the suggestion about the control knob, it stays lit when I switch over so I guess it has snapped off inside. Does anyone know how to replace it please or is there a workaround for the winter that sets it to water and heating?
  7. G

    Some Advice please before I call a Plumber?

    Thanks for the suggestions so far: The pump I refer to is the one in the boiler, but I'll try to give it a tap or turn it( thinking about it , it has not done the anti frost cycle run for about 10 secs recently) The pressure is at 1.5 bar so I guess is OK The display stays the same when I...
  8. G

    Some Advice please before I call a Plumber?

    Sorry should have mentioned the pump I refer to is the central heating pump and that there is no room thermostat, it is just controlled by the timer clock and boiler stat.
  9. G

    Some Advice please before I call a Plumber?

    I have a Vokera Linea 28 which has been on the 'hot water' setting all summer and worked fine. Now it has got colder I have switched it to 'combined heat and water' and the pump does not kick in, despite me switching the time clock to "constant" and turning the stat up to full. I've has a...