    End tile mortar shelf

    Yesterday I was fitting some eaves protector to a small section of roof where I recently noticed water was pooling and leaked into the home when it was heavy. This part of the job was fairly straightforward but I noticed on of the end tiles the “sheet” that holds the mortar was loose and broken...
  2. G

    Incoming Mains Water - Odd Pipe Work

    Hi I have lived in my home for well over ten years now and it has always frustrated me as to what this pipe work under the stairs was all about due to the fact it looks to be a right mess. I am wondering if anyone can shed an light onto what the various components might be doing. I know the...
  3. G

    UPVC Window Rubber Seals

    Dear All I know you are able to buy the replacement rubber seals for the side that is removeable but is there any way to replace/repair the rubber seals that are attached to the plastic window frame itself; on mine this is on the outside? Thanks
  4. G

    Large Junction Box

    Thanks guys I feel that item...
  5. G

    Large Junction Box

    Sorry guys I am not home at the moment to take a picture but the cores are similar to this: http://thumbs3.ebaystatic.com/d/l225/m/mx275u0BKt6fm1LI0KkwR3w.jpg
  6. G

    Large Junction Box

    That is correct Iggifer - spot on. But whereas in your image the cables have a single core my have multiple core so am unable to really get more than say ring in & ring out within the connectors. Make sense?
  7. G

    Large Junction Box

    Thanks for the links guys. The issue is that the three different cables have so many cores that it is diffcult to fit them all into the connector blocks & I assume it is not good practice to remove some of the ends of individual cores to free space???
  8. G

    Large Junction Box

    It will be internal and the three cables are all 2.5mm.
  9. G

    Large Junction Box

    Hi there Yes it is twin and earth. I can send a photo of easier. Can you send an example link of a JB that would do the job. Thanks
  10. G

    Large Junction Box

    Hi Guys I have a cable run directly from my CU to my garage attached to my home. I want to utilise this feed approx half way along and spur off it but this then gives me the feed, the existing continuation and then the new extension I want to add. Thus far I cannot seem to find a junction box...
  11. G

    Large Junction Box

    Hi All I want to install a junction box that is capable of connecting three 32-amp mains cabled but everyone I have tried so far just doesn't have the capacity due to the thickness of the cables; the terminal connectors are too small. Is there any recommendations for doing this? Thanks Graham
  12. G

    Hotpoint WMD962 Drum Bearing Replacement

    Dear All The bearings on my Hotpoint WMD962 washer sound like they are on the way out. I was wondering if it is worth the effort doing the job or paying for a repair? Looking online you cannot buy just the bearings & have to replace the whole drum unit which looks like a big job and the part...
  13. G

    11.5v Electronic Transformer VS 12v

    I got this cheap Wickes one as per previous post: http://www.wickes.co.uk/Wickes-105VA-Electronic-Transformer/p/162383
  14. G

    11.5v Electronic Transformer VS 12v

    Dear All Just to jump in mid conversation; I swapped the Screwfix unit out for a single output 12v jobby and full brightness has returned. Bye for now.
  15. G

    11.5v Electronic Transformer VS 12v

    They are 10W 12v