Recent content by hammer it

  1. H

    bloody room thermostat!!!!!!!!!!!! honeywell>drayton

    problem sorted diverter valve head knackered , pumping against a closed valve , opened manually ,and bobs your uncle ,hot rads after a freezing night.
  2. H

    bloody room thermostat!!!!!!!!!!!! honeywell>drayton

    took on what seem to be an easy task of swapping a honeywell room thermostat for a drayton combi-stat rts8. i have 4 wires red (live) blue(neutral) yellow (heating demand) and earth, in honeywell red was wired to pin 1 , blue to pin 2 and yellow to pin 3 , earth not used, instructions for the...
  3. H

    padstone size

    called him back and bobs your uncle 200x150x100, no SE needed.
  4. H

    padstone size

    im gonna be removing a loadbearing wall and inserting an RSJ , just under a 3 metre span. been on the phone 2 day to the local BCO and he said the rsj should be 7inches x 4inches, but i forgot to ask him the size of the padstones, just wondering if anyone could help.
Back