The make of all the windows & doors I'm installing is Euramax.
There deepest sill is 185mm. Haven't actually opened the packaging yet to see if there are straps / clips for fitting. If there are none included I will most likely screw through the frame into outer leaf with frame fixers.
I...
Thanks for all your input.
Yes the BCO said fitting windows in the middle of insulated cavity is all about thermal bridging so reducing chances of condensation issues around the reveals. He did add that this is the ideal and whenever a window is fitted to the outer leaf then insulated...
Hi.
Asking this question here as well as window section as it's a building & regulation issue.
I have new upvc windows & doors to fit in my new extension with 150mm deep external sills. The BCO has said he wants them fitted in the middle of insulated cavity closer ( screwed into thin...
Hi. I have new upvc windows & doors to fit in my new extension with 150mm deep external sills. The BCO has said he wants them fitted in the middle of insulated cavity closer ( screwed into thin plastic?!! ). Obviously if I fit them there the external sill will not over hang and be sitting on the...
I would like to build my 2 storey extension around the existing single story extension so we can carry on using it (part of kitchen) then once new extension is water tight, knock the old one down.
I understand this is probably unusual and it no doubt would be easier to knock it down first, but...
Thanks for all your help. BCO wants a wall plate fitted. So sounds like the right way to do it would be to stop the wall plate at the inner skin and make up the roof size by making and adding on a gable ladder which rests across both skins.
Hello. I am building a single story extension with a flat roof at the back of our bungalow. The roof joists will be hung on joist hangers on timber bolted to the existing house wall and resting on the timber wall plate at the other end. I am now ready to put the 4x2 timber wall plate on the...
It's a fair size. approx 2.7m wide and about 5m long. I know this does seem a lot of light though. Maybe 6 would be enough but i dont want to create shadows by not having enough light. Thanks for your help. :o
Thanks i'll daisy chain em then and keep the earth continuity going with terminal blocks. This circuit will have a total of 1100w and will be protected by a 6amp mcb. I understand this to be ok. So the flat grey 1.5mm cable is ok then, it doesn't have to be special heat resistant cable? Thanks...
I want to wire 8 down lights (50 watt Halogen no need for transformer type) in my kitchen. Would anybody be able to tell me the best way of doing this please. I\\\'m thinking of either using 3 junction boxes and join them there or just more simply going from the first light to the next and so on...
I have searched the whole site but can not find an answer. I want to wire in a 3kw single fan oven, a 5.8kw ceramic hob and an extractor hood which uses 150-250watt all from the 6mm cable from consumer unit and passes through the dp cooker switch. is this possible? my idea is to run the 6mm from...