Recent content by Hotrod99

  1. H

    Advice needed on "double insulated" metal light fitting

    from the drawing they provided, i can't see how the light can still be double insulated if any single sheathed cable or connector is located inside the metal rose, in a fault condition the metal rose would become live. Am i missing something?
  2. H

    Advice needed on "double insulated" metal light fitting

    Thanks, useful info, i am guessing that hundreds of lights similar in design to this are being installed by non qualified people who don't realise that they are turning the light into class 1 by placing wiring or connectors inside the rose.
  3. H

    Advice needed on "double insulated" metal light fitting

    are there no manufacturers making a product suitable for installing in the rose? Would putting the earth to the rose be creating further dangers?
  4. H

    Advice needed on "double insulated" metal light fitting

    Needing some advice for installing these lights safely, they are deemed as double insulated, but only if the supplied enclosed connection box and its sheathing are used and feed to the wiring connections outside of the fittings rose. the pendants have a metal rose that attaches by 2 screws to...
Back