Recent content by inasnum

  1. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Think its already been there and done that :oops: its in the loft and at some point in the past it has leaked (old water marks) not sure what would of caused it! It has got a newish expansion tank fitted externally.
  2. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Doesn't sound good! What problems will I be facing then?
  3. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Cheers Guys thanks for the advice.
  4. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Thanks Bella, winds me up that BG always try push new boilers on people! In our last place we had an old BBU changed out (not BG a local installer), and after a couple of years they were still trying to push on new boiler on us!
  5. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Hi guys, boiler model is GW 24Ci - no part is required, works fine just that BG say the parts are obsolete which doesn't sit right, must be around 10 years old but I would of thought parts are still out there!
  6. I

    British Gas Advising New Boiler Due to Obsolete Parts

    Hi All - Just had my first service of our boiler in new house today. We have a combi boiler Gloworm 24i, with Combi Mate and Magnaclean fitted. British Gas are advising us to get a new boiler as parts are obsolete for this boiler. Just wanted to check on here what peoples opinions are - seems...
  7. I

    central heating costing a fortune!!

    I have never checked my weekly usage but we have a 15 year old Baxi Back Boiler (bungalow 8 rads & Gas Cooker). When we first moved in a year ago BG charged us 50 quid a month direct debit - however we have sinced serviced the boiler and powerflushed. Our bill (bearing in mind Gas has gone up)...
  8. I

    baxi bermuda 552 back boiler no hot water , please help!!

    Possibly 3 Way valve sticking? I had the opposite problem a while back (hot water but no heating!)
  9. I

    Ventilation for a back boiler

    I had the same issue with my Baxi Bermuda Back Boiler - google for a 100CM Stadium Vent, this will meet the current regulations.
  10. I

    Baxi Bermuda Inset 2 not fully firing

    I have had similar problems with our baxi bermuda. It could be the thermostat, thermocouple or gas valve! (we have had all these parts replaced in a short period of time) Boiler works great now - however we recently had a another similar problem (Boiler Fired up for hot water but not heating)...
  11. I

    Baxi Bermuda boiler 552

    I have the pleasure of owning one of these! To light the boiler pilot light: 1. Press and hold in the grey push button at the same time pushing in the igniter button until it clicks 2. Push the igniter button repeatedly until you see the pilot flame alight through the viewing window. 3...
  12. I

    Baxi Bermuda Back Boiler Replacement

    Hi to all, I have been reading this forum now for the past 9 or so months after buying our first home (very useful resource!). I am seeking advice for the replacement of our baxi bermuda back boiler (should have saved enough by mid next year!) I had BG come over to give a rough estimate...