Recent content by ITGURU

  1. I

    G2-12 Battery Issue

    Definitely not the zone (device) battery issue despite coming up - i replaced all wireless devices with fresh new batteries!
  2. I

    G2-12 Battery Issue

    whats the difference between the 2 battery events? i love firmware/software testing - whoever wrote it needs to do a better description! lol
  3. I

    G2-12 Battery Issue

    If it was blown wouldn't this cause further issues or be permanent as it clears itself after a moment.
  4. I

    G2-12 Battery Issue

    No I havent - could it be failing rather than blown?
  5. I

    G2-12 Battery Issue

    Hi, Just wondered if anyone can assist. For a while now on my Galaxy G2-12 I keep getting alerts approx every 24 hours (which i assume is a self test interval) of: +BAT MIS -BAT MIS -BATTERY +BATTERY I've changed the main backup battery and all batteries in all Wireless devices - PIR, Door...
  6. I

    Honeywell PIR Wiring

    Yes the model I have doesn't come with EOL resisters included and I think you forgot to attach something ? thanks.
  7. I

    Honeywell PIR Wiring

    Hi Everyone, I've previously setup an alarm system with honeywell 8ir103 PIRs with the resisters etc. I'm installing another G2 system and the PIRs are end of life so now using IS312 PIRs. Can someone just clarify which terminals on the PIR i use for each of the 2 data cables, and I presume i'll...
  8. I

    Wiring for 12v DC doorbell alongside twin and earth

    Thanks, i just wasn't sure with it being low voltage and very thin cable that it should be ran the same route as all the twin and earth grey cables.
  9. I

    Wiring for 12v DC doorbell alongside twin and earth

    I want to install a 12v dc smart doorbell and run the cabling under floorboards along the joist cable clipped, along with all the twin and earth etc cables. However, am i correct that I cannot run the standard bell wire alongside/near the main 240v twin and earth lighting/socket cables? I might...
  10. I

    Galaxy Peripherals

    Ta! I'm guessing for normal domestic install a power rio wouldn't be necessary although if say have a 50 zone flex with say 10 pirs this would still be under the main panels power capacity.
  11. I

    Galaxy Peripherals

    Thanks I thought that might be the case. I just think logically that if the keypad is connected to a rio and the rio fails the whole system will be down but if keypad wired back to panel the rio can fail and keypad still work. so my plan would be to have main panel in loft, belden cable between...
  12. I

    Galaxy Peripherals

    Is that the only supported configurations a single daisy chain or panel being in the middle. How many lines out can I run from the panel. Just not always possible to locate items as part of the chain and always better to have keypad direct to the panel rather than a rio so that if the rio fails...
  13. I

    Galaxy Peripherals

    I have a galaxy panel which currently has a keypad linked straight to the panel in the loft using all on board zones and an RF portal next to the keypad daisy chained off the keypad. My question is how many data lines can be run off the main pcb from the A B data line if I wanted to add another...
  14. I

    BG Doorbell Transformer

    it's this model Hikvision Video Doorbell WiFi model DS-KB6403-WIP
  15. I

    BG Doorbell Transformer

    Thanks all. So what alternative could I use without using the cheap and high failure rate of standard plugin 12v dc transformers that you can get generically off the internet. looking for something a bit more reliable.
Back