Recent content by Jackfm

  1. J

    Galaxy Dimension 48 Lid Tamper Fault

    Thanks, I have it in engineering mode for now untill I look to replace. Unfortanlty I diddnt buy from yourself and I cant re-call where the seller was based. I have your LCE-01 Module which I see doesnt work with V3 Flex. Looks like I'd need the A083 module, Does the A083 Module work with selfmon?
  2. J

    Galaxy Dimension 48 Lid Tamper Fault

    Yeah i disconneted the green leads and jumpered them, still got the tamper message. Yeah mine is random too, can 1 be time, might be 4/5 in a row before itll clear and let me exit engineer mode. Purchased off ebay back in feb. Can I turn off output 0003 so it wont alert?
  3. J

    Galaxy Dimension 48 Lid Tamper Fault

    Hi all, Had my GD48 installed since March, every so often I’d get 003 Lid tamper alarm, extract below from self mon. Last month, i finally got around to having a look. I thought perhaps I had a faulty tamper switch so I disconnected the lid tamper switch from the board and just made a loop...
  4. J

    Galaxy Dimension 48 Upgrade from a G2-20

    I’ve worked it out... I set the exit time to 030, so i get the countdown with part set and with full set it will countdown but on final closing it will set. I’ve set the internal sounder *99 to strobe so it only sounds on alarm, and set my part-set keyswitch to #, which means when it’s turned...
  5. J

    Galaxy Dimension 48 Upgrade from a G2-20

    Do you know if I can use a keyswitch to set this? Cheers
  6. J

    Galaxy Dimension 48 Upgrade from a G2-20

    Hi, Yep its used at night. Part set also did this on my g2-20, but not on my dimension... can't find the setting for it!
  7. J

    Galaxy Dimension 48 Upgrade from a G2-20

    I've just upgraded our home alarm to a Dimension, I've nearly got it where I want it in terms of config, but I'm stuck on a few points, hoping one of you may be able to help. On the G2-20, When fully setting the alarm (A Key), The alarm would not set untill the final zone was closed (Exit time...
  8. J

    Galaxy G2-20 Keyswitch Zone Help

    Perfect all working, thank you very much
  9. J

    Galaxy G2-20 Keyswitch Zone Help

    thank you, that explain's the readings! So i think understand what you're saying re circuit wiring, I've quickly drawn it out, is that what you mean? As when the relay is not energised, the circuit will go via NC on the relay, so 1k in the circuit total? Then, when I turn the relay on, the...
  10. J

    Galaxy G2-20 Keyswitch Zone Help

    Hi All, Does anybody have any experience with wiring up key switch zones on a Honeywell galaxy system? I seem to be stuck with getting this to work. Instead of an actual key switch, I want to use a relay to allow remote setting/un-setting. Looking at the manual, I need to change the...
Back