    rising main problem

    All sorted a nights sleep helped, there was an air lock on the cold feed side,we blew water from the tap at the top of garden through the cold tap. then opened the bath taps dropping the level in the cws tank,which opened the float valve n cws, then we opened the stop valve and were able to see...
  2. J

    rising main problem

    Cheers Sammy1990 Hello hotly it's a gravity fed spring main entering the house then going through a uv filter then up to cws tank in the attic all taps are fed from the tank. We can disconnect the uv filter turn water on and we have no drop in flow. Once the the uv filter is put back in...
  3. J

    rising main problem

    A friend of mine has his water off a spring,he has good pressure at the stop tap but when it's filling the uv chamber it starts to slow then 3/4 up the jar it stops to a trickle. The outlet side runs up to the cold water store and these he has told me are full. There is no obstruction on the...