Recent content by Joelc

  1. J

    Third Party Certifiers

    What's the difference? I didn't think there was need for a full submission with regards to electrical work.
  2. J

    Third Party Certifiers

    Thanks, I think the LABC either are misinformed or are just trying to put off this work. I want to comply with the law obviously - however I don't know why it has to be as difficult as is. One question, if I go via building notice, and I do the testing - should that be satisfactory for...
  3. J

    Third Party Certifiers

    Thats what I see being an issue - however it will put people in a situation where they cannot complete DIY work, especially if the LABC are pushing people down that route.
  4. J

    Third Party Certifiers

    Hi All, Given that getting a straight and clear answer out of my LABC is like herding cats, I have changed plans and am looking at getting a third party to come and certify my electrical work. To be clear, I have not yet started the work, as per the regs, so I need to either have BC involved...
  5. J

    What is a competent person?

    BS7671 in this specific instance, but as you say, there is a lot of inter relation between the standards that cause confusion, and are all open to a level of interpretation which unfortunately not everyone sees the same way, which leads to both confusion and in some cases misinformation.
  6. J

    Power Factor when Designing Circuits

    They seem to think they can upgrade to 80a without any cable upgrades, but the drive is coming up soon, so I may opt to have the service cable upgraded at the same time. However this may be more difficult as they were unsure if I am on a shared supply, so I'm waiting for them to do survey and quote.
  7. J

    Power Factor when Designing Circuits

    Seems like its a can of worms. The calculation makes no difference to the final circuit outcomes, so I presume it's to be ignored. Just seems odd to have it in there in the first place. It seems its not worth factoring in for domestic installs. I was reading the same thing, and I couldn't get...
  8. J

    Power Factor when Designing Circuits

    Amtech ProDesign - the domestic version. I'm not entirely sure why its factored into the software if it isn't applicable.
  9. J

    Power Factor when Designing Circuits

    Thanks all, the software I am using has .88 as a baseline so I just wanted to make sure that was correct, given some of the defaults are already iffy.
  10. J

    Concrete hearth & ceiling insulation

    Hi all, Bit of a mixed one here. The old concrete hearth is quite soft and crumbly. Should I attempt to fill in the parts of the hearth where they are pitted, to smooth it off, some of it will be covered by the wooden frame I will be building round the chimney, but I'm not sure of I need...
  11. J

    Power Factor when Designing Circuits

    Hi All, Currently preparing for a DIY house rewire, I am now designing the circuit layouts and doing all the calculations for the new circuits before i put my notice in to the LABC. I am working out the load on the individual circuits to calculate cable sizes etc. However - I'm not sure...