Recent content by jrt

  1. J

    Viallant Time Clock Issue

    It goes into terminal No4. The old clock worked ok like this and it has the same backplate. The only way I can get it to stop is gy turning off the heat and water dials on the front of the boiler. The stats and programmer do not have any effect. Could it be the diverter valve? Thanks
  2. J

    Viallant Time Clock Issue

    Hi All I have a vaillant eco tec plus condensing boiler. All was well until my micro gyr timer clock seemed to go faulty. The boiler was always calling for heat and water no matter what the timer said on/off etc. I thought it must be the clock so i changed it for a siemens rwb29...
  3. J

    Link Detached pitched roof

    Thanks again Woody Right i spoke to building control he said he will only come out and inspect at the end of the job. Spoke to planning they said i live in a semi detached already so there is no issue. The pitched roof,write a letter of complaint but they can just get planning permission for...
  4. J

    Link Detached pitched roof

    Thanks for the reply Woody The previous flat roof was fixed to my wall but sloped to the back away from my house.I presume they can now fix this roof to my wall but the concern is all the rain water off my main roof and next doors main roof will go into this gully. If next door do not keep...
  5. J

    Link Detached pitched roof

    Hi All Next door are having an extension built and i have posted before about my concerns but have some more :shock: I live in a 1970's linked detached, linked by a flat roof with an up and over garage door front and back. It is a row of 4 houses all looking the same. Next door applied...
  6. J

    Extension Next Door

    Thanks for the help Update is i have managed to speak to building control officer. He says they have 5 years He has checked the footings and allowed them to pour and did not affect my foundations.He did say that i should of been notified regarding party wall act...
  7. J

    Extension Next Door

    Woody Thanks for the reply. I am not really concerned about that its just that you cannot point the wall if needed and i am concerned about debris off the roof falling down it and causing damp.Do you think this is an issue. I have not but again i am no expert and presume they are...
  8. J

    Extension Next Door

    Could you help please. I live in a link detached house joined by a flat roof with a garage door front and rear. In the area behind the rear garage door next door are building a kitchen extention. This will come all the way up to my wall leaving a gap up to a 6". My concerns are a...
  9. J

    vaillant ecoTEC plus 428 s.53 code

    Cheers I can change the boiler wiring so i have a permanent L/N/E .I then am left with the switched L/N/E from the upstairs junction box.If i put the switched live into No4 do i put the N into No5? Sorry to be a pain but the instuctions show different options and i seem to be somewhere in...
  10. J

    vaillant ecoTEC plus 428 s.53 code

    Pump is set to max 3 Reduced D0 to 15 and left it on all night still had heating in the morning :D Came home today from work and it is showing s.53 again :? It looks like i may have to give the system another flush maybe :?: Can someone explain how the pump over run should work as...
  11. J

    vaillant ecoTEC plus 428 s.53 code

    Cheers for the help I seem to be making a mess of trying to explain myself in the post i will try and be clearer if i can sorry The old feed to the original boiler L/N/E is the one i used so this does turn the display off to the new boiler when the clock switches off.The live i meant when in...
  12. J

    vaillant ecoTEC plus 428 s.53 code

    To be fair i did not install the boiler originally so i would not have put the pump and wiring under the floor.It is the click stuff so i can get to it if needs be. If i need to change the configuration i can take it up if thats the way forward.I just wanted to paint the picture that i could...
  13. J

    vaillant ecoTEC plus 428 s.53 code

    Can anyone please help? I have two possible issues 1. I installed with my father in law (Corgi REG) a Vaillant open vent bolier to replace my 20 year old gloworm spacesaver. The electric valves,cylinder stat,room stat,pump were all wired up to a junction box(under daughters bedroom...