  1. K

    Baltur (EOGB) burner morning and afternoon lockouts

    Thanks for taking an interest and for te many helpful comments. Im a however a little confused by the comments regarding the 15mm pipe. Suction line vaccum is determined by two things. The height of the lift and the friction losses in the line. The friction line losses increase with...
  2. K

    Baltur (EOGB) burner morning and afternoon lockouts

    Thanks, I will revert to a new S nozzle as i now have some spares and put the gauge on the pump at cold start and check the figures.
  3. K

    Baltur (EOGB) burner morning and afternoon lockouts

    John Yep it burns the first stage for about 20 seconds before switching to full pressure if the heat demand is high enough. Pressures were 10bar and 22bar if i remember correctly.
  4. K

    Baltur (EOGB) burner morning and afternoon lockouts

    Newbie posting :roll: Having some difficulty with our Baltur BTL6P (EOGB). 2 stage Initially very occasional lockouts associated with what we believed to be fuel starvation (empty tiger loop and filter) tank is lower than burner. The location of the tigerloop filter and firevalve was...