Recent content by Kocher

  1. K

    Failed/blown concrete lintels - replace or repair?

    I have noticed signs of the old cast iron gutter joints leaking (due to be replaced) above each ends of the lintel, this could be a reason for the 1st floor lintel but no idea what’s causing the ground floor lintel reinforcement corrosion. Also if it’s gutter in the case of 1st floor, how come...
  2. K

    Failed/blown concrete lintels - replace or repair?

    I’m thinking the same, but a vertical crack right before the bearing worries me a lot. I have attached some pics for more info. I did brush off some of the corroded bar and it seems like not completely corroded so a patch repair could do it. FYI that plasterboard adhesive is something very strong!
  3. K

    Failed/blown concrete lintels - replace or repair?

    Two inner concrete lintels(100x~250) supporting 1/2 of external 30s solid walls, one supports a 1.8m window opening in 1st floor (carrying 3 courses and roof) and the other a 2m window opening in ground floor (supporting 10 courses and then an exact size window opening in 1st floor), are blown...
  4. K

    RSJ Padstone - HELP

    Thanks guys. You can tell I had fun being bounced around by the BCO, builder and the steel fabricator.
  5. K

    RSJ Padstone - HELP

    Builder doesn’t agree, with 10mm plate, says it will increase brick joints massively and not practical, even the 6mm. So I’m going for RSJ for inner leaf and IG C lintel for outer leaf, gauge is 3.2mm and 225mm high. Both not bolted.
  6. K

    RSJ Padstone - HELP

    An update guys: I have taken one of the RSJs back to weld an underplate to it and the steels guy said stiffeners will stick out on my wall so I can’t use that. I contacted the BCO prior to confirm they are happy with the underplate, the BCO said okay, but either 6mm plate with stiffeners or...
  7. K

    RSJ Padstone - HELP

    As shown in the photo
  8. K

    RSJ Padstone - HELP

    Only if my cavity width was enough to fit one of those ... :unsure:
  9. K

    RSJ Padstone - HELP

    In my colleagues defence, I didn’t tell him about the stiffners and a told him of a wider opening then. I have contacted the steel fabricators and they quoted me ~£100 to weld a 6mm plate to under one of the RSJs. Catnic recommends a box lintel (BHD100) for inner leaf and an angle lintel...
  10. K

    RSJ Padstone - HELP

    Thank you guys for coming back to me. I agree with you too. I had a look at cantnic or similar lintel provider products, but the capacities given on their websites didn’t seem enough, unless I got for the i beam with a welded under plate lintels, that is massively expensive. I could have...
  11. K

    RSJ Padstone - HELP

    I’m creating an opening (Proposed 1700mm wide) in my rear external ex solid wall (it has been rebuilt using cavity with a width to match existing, 230mm, just in ground floor and half length of the wall). There is a small window and a 900mm door in that wall panel I want the opening in for the...
  12. K

    Thermal plasterboarding solid wall/internal insulation - advice please

    Just bare bricks. Although I did forgot to add that, the roof has some holes in it that hasn't been touched for years (I found this thanks to google streets view history) also a roofer told me the gutters need changing too as they are the old cast iron ones (all pending repairs). I have bought...
  13. K

    Thermal plasterboarding solid wall/internal insulation - advice please

    Hi, First time posting here, I have taken all the plaster off on the external solid 9" walls (1930s house) and now want to insulate and redo them using celotex 37.5mm thick 2.4mx1.2m plasterboards. I have heard many stories about damp and condensation issues caused by internal insulation. Do...
Back