Recent content by kordiun

  1. K

    Potterton netaheat that has flummoxed all!

    By the way, the pump seems to be working, it was new about 6 months ago.
  2. K

    Potterton netaheat that has flummoxed all!

    Agile what is your number, really don't want to buy a new boiler!! I suppose they did not even use a test meter? :(
  3. K

    why does my programer remain on?

    ok, given up. After fuse going constantly (3amp), replaced PCB, air switch, fan, engineer couldn't work out what was wrong with my potteron netaheat boiler. Suggested I put in a new , programer, which I have, but no joy, stills system doesn't work, even pump stopped now! But programer remains...
  4. K

    Potterton netaheat that has flummoxed all!

    I have a potterton netaheat, been great and reliable until now. Flummoxed most heating engineers. It started blowing the 3 amp fuse and fuse on the psb. So a new psb, air prssure switch put in, timer but still not working, so new fan put in, still not working. Any ideas please? :(
  5. K

    Potterton netaheat whats gone wrong?

    By the way, yes the 3 amp fuse blew too.
  6. K

    Potterton netaheat whats gone wrong?

    Wires tested using multimeter test ok. Both fuses were blowing when the timer switched system on. Now not blowing, pump sounds like its pumping but fan not working.
  7. K

    Potterton netaheat whats gone wrong?

    I have a potterton netaheat, been fantastic until now. Flummoxed most heating engineers. It started blowing the fuse on the psb. So a new psb, air prssure switch put in, still not working, so new fan put in, still not working. Any ideas please? :cry:
Back