Recent content by kotewala1

  1. K

    adding new toilet downstairs, vent pipe or no vent pipe

    Thank you to BLUP and to Dereekoo for your reply. The first floor Basins are connected to the soil pipe as shown in pic Black pipe connects to soil stack . I do not think it has a U bend plz c pic. Should it have a U bend ? The ground floor new toilet is connected to new soil pipe as shown...
  2. K

    adding new toilet downstairs, vent pipe or no vent pipe

    Drainage 1. new down stairs toilet against outside wall . Pipes had be at outside at side of house. Builder put them almost on the surface, saying if he puts them deeper they will not connect at other end into the inspection chamber. Is this acceptable? I now cannot creat a path eg blocks...
  3. K

    micro - copper ripped out , replaced with 10mm Hep20

    House complete refurbish. Installer , ripped out existing copper micro bore and replacing with 10mm HEP20 and said running about a metre of 15mm to each Rad. Said it creates more pressure and provides more heat. Is this true ? Secondly, said need new water pipe of 25mm from road to house...
  4. K

    Boiler loses pressure when LOO is flushed

    I apologise that was not my intention, neither did I know capitals meant raised tone, it was to highlight or emphasise
  5. K

    Boiler loses pressure when LOO is flushed

    Totally unhelpful and unnecessay
  6. K

    Boiler loses pressure when LOO is flushed

    pressure does NOT drop if wc not flushed or vanity tap not used
  7. K

    Boiler loses pressure when LOO is flushed

    100 % correct . Teed into hot and cold from Boiler. Feeding the Cold to cold cistern . Hot from boiler to tap on vanity sink . Any easy solutions?
  8. K

    Boiler loses pressure when LOO is flushed

    Boiler NEVER loses pressure if I dont flush or dont use tap in loo room
  9. K

    Boiler loses pressure when LOO is flushed

    he said nothing to do with him. he left it working . Plumber who installed downstairs toilet T into heating system
  10. K

    Boiler loses pressure when LOO is flushed

    Gas safe installed new gas boiler and heating. Then another plumber installed the downstairs loo. Now when I flush the toilet the boiler loses pressure to zero and has to be filled every day. Even if I do not flush toilet pressure drops and I refill every day. The plumber did connect to two...
  11. K

    Bay window Radiator Brackets

    I know cannot understand why no brackets welded on back. Also no feet . Also the curve makes it difficult to attach any bracket on top due to the distance from wall.
  12. K

    Bay window Radiator Brackets

    Bought curved bay window rads. They have no clip on back for std radiator brackets to clip into. Any ideas as to what to use or would I need to have brackets welded on rads. appreciate any ideas
  13. K

    Moving radiator pipe

    Thank you Dilalio. What bracket should you use, to come from the wall?
  14. K

    Moving radiator pipe

    I am trying to move radiator into different position, on ground floor . Half the floor is floor is boards the other half is concrete. See pic. I want a vertical rad along the wall. at present it was horizontal rad. question . how do i route from present position to along the wall...
  15. K

    Hi everyone

    Hi everyone