Job example.
Replace existing combi boiler, connect new flex to existing fused spur or socket. No alteration to existing circuit.
Is a minor works cert and part p reg required?
Just had a new kitchen installed and on the cornice in a couple of places exess mitrebond has squeezed from the joint. Is there any way of safely removing it without damaging the gloss surface underneath?
If an old type u6 meter is installed with two anacondas and no bracket then gas fraud is poss without even removing the meter. But that aint a gas safety issue.
You have to remove the green plug with the two leads fitted from the condense trap. Snip off the two spades from the inside of the plug so there flush, then fit the elbow pointing upwards in the place of the plug then refit the plug on the top of the elbow.
Its a fault with the condense trap. Get it fixed free under warranty. Remove the front panel and and the back left you will see two wires entering the condense trap via a blue plug. Remove the white HT lead and tape it up. The boiler will work fine. The problem is the probes get wet and the...
Left my 16 yr old apprentice on the job today with an old chainsaw to cut the boards. Got back to the job after being in the pub for 5 hours and he'd put a small scratch in the 1.5mm lighting cable. What should i do? I was thinking maybe the chainsaw need sharpening.
Sorry but had to reply!! If you are 1- 2mm into the surface then your into the pipe as the wall thickness is 0.9mm (22mm tube or 0.7mm 15mm tube). So if your only 0.35mm in ya half way through! turn the gas off and get it sorted.
Called to a job last october. Rads pinholed and the system water rust brown. BG had been looking after the system for years and after replacing two rads told them there cover was no more until the problem was solved.
The existing system consisted of a Albion thermal store linked to a Baxi Solo2...
Ther are pots for "ignition capacity" (which i had to adjust to prevent ignition noise) , central heating capacity along with hot water. The inlet pressure was 19mb and CO to CO2 ratio 0.000. Sorry if a few mistakes as its late friday and the beers been flowing.
The old Solaris used to whistle a bit but the Sargon is howling!
The Solaris fan was FIME but yesterday after checking the Sargon fan there was the SIT stickered logo on the top right.
Installed the new Sargon 35 yesterday, what the hell is going on?! Sounds like its about to take off to fu**in mars! The premix SIT fan vibrates like hell and makes a low frequency drone on slowing to low load. Talked to the local heatline guy today who said "its a noisyboiler".