Madrab's latest activity

  • Madrab
    Madrab replied to the thread Underfloor heating problem..
    Need to step through the different components to narrow down circulation issues > pump > mixing valve > manifold airlock > zone valves...
  • Madrab
    Presume you mean JG, not JD?
  • Madrab
    Madrab replied to the thread Can this be removed/cut.
    Yeah - if the plumber removed the toilet and disconnected that from the old cistern overflow then if he is a plumber and not just a...
  • Madrab
    Madrab replied to the thread Landlords Gas Test.
    Usually the MI's for the cooker will specify clearances to flammable surfaces, electrical outlets, heights to extractors etc, that's the...
  • Madrab
    Madrab replied to the thread Push fit problem.
    Yes - the Superseal inserts are specific to JG, no one else uses them, therefore may cause more issues with ID size and fitment. I have...
  • Madrab
    Madrab replied to the thread Wetroom drain - is this normal?.
    Absolutely not, that needs looked at sooner rather than later but that could end up a real can of worms if it's a wet room. That metal...
  • Madrab
    Madrab replied to the thread Push fit problem.
    @Jamie3147 - All pipework be it plastic or copper has an OD specification of 15mm, that allows their pipe to use standard sized...
  • Madrab
    Madrab replied to the thread Fixed or hinged return.
    That's a really weird install. Where they located the shower and rain head etc then there was no way that little piece glass was going...
  • Madrab
    Madrab reacted to flameport's post in the thread Fixed or hinged return with Like Like.
    Rip the whole lot out and fit items which are appropriate to the space. Worst 'refurb' ever.
  • Madrab
    Madrab reacted to foxhole's post in the thread Appliance valve - hep20 with Like Like.
    Replacing ,though with mains valve so handy hardly seems worthwhile .
  • Madrab
    Madrab replied to the thread Tap in wooden kitchen worktop.
    Use waterproof PVA glue to seal the cored wood grain in the hole, silicone can lift after time leaving the wood exposed, wood dependent.
  • Madrab
    Madrab replied to the thread Push fit problem.
    Try HEP inserts
  • Madrab
    Madrab replied to the thread Push fit problem.
    PB H&C Services & Central Heating - that's the old HEP pipe IIRC. It's Polybutylene, OK for water services but if it is the old stuf...
  • Madrab
    Madrab replied to the thread Pan Connector not central.
    Most basin have what's called a slotted waste - where the overflow is built into the basin casting and drains out through a slot in the...
  • Madrab
    Madrab reacted to dilalio's post in the thread Pan Connector not central with Like Like.
    Block up the cistern overflow as new one most likely to be internal overflow... Down the pan... Or it should be!
Back
Top