  1. M

    Replacement outdoor PIR

    Manufacturer has advised there is no min load. The output from the OS001 is via a relay, it is on or off (on activation) and the relay contacts are rated to switch 225Watts of LED Load. So the half brightness state in auto mode remains a mystery.
  2. M

    Replacement outdoor PIR

    Will try a filament bulb instead
  3. M

    Replacement outdoor PIR

    Gave this a go with a 50w LED and the same outcome
  4. M

    Replacement outdoor PIR

    Its a 30w LED, I see the PIR has a max 225w but no minimum is stated that I can see
  5. M

    Replacement outdoor PIR

    Hi all, I had a very old outdoor PIR (Smiths, no model number) connected an LED floodlight, which is also linked to a one way switch. The PIR seemed to have failed as the light only flashed on when it detected movement (no ability to adjust time on). I have got a Knightsbridge OS001 to replace...
  6. M

    Nest Thermostat E / Ideal Independent c24

    Ok thanks! But one question.. what does goosed mean???
  7. M

    Nest Thermostat E / Ideal Independent c24

    Image of Heat Link wiring here. Thanks all for the help so far!
  8. M

    Nest Thermostat E / Ideal Independent c24

    I have left it maybe 2-3 minutes. Mainly because I have had a Nest before and it normally kicks out almost instantly.
  9. M

    Nest Thermostat E / Ideal Independent c24

    Hi all, I have fitted a Nest Thermostat E and wired NO and C from the Heat Link to my Ideal Independent C24 as shown in the attached photo, having removed the jump (there was no previous room stat). I have switched the boiler to manual on. The heating continuously runs, even when I turn the...
  10. M

    Extending BT socket

    I mean router and/or phone, obviousuly!
  11. M

    Extending BT socket

    Something like this? https://www.amazon.co.uk/gp/product/B003H6GUNA/ref=as_li_qf_sp_asin_il_tl?ie=UTF8&tag=increasebroadbandspeed-21&linkCode=as2&camp=1634&creative=6738&creativeASIN=B003H6GUNA And then I can run the slave and have the router and/or broadband in either location as I choose...
  12. M

    Extending BT socket

    A follow up question would be... by Master socket has one outlet into which a microfilter is plugged (tat the router is plugged into, phone empty as not used). Can I replicate this setup at the new slave socket? I'm thinking along the lines of, if i ever want to plug a phone in, will i be able...
  13. M

    Extending BT socket

    Found a kit on eBay, looks ok to me.... for anyone who might find useful, this link should work while the listing is active http://www.ebay.co.uk/itm/2-Pair-CW1308-WHITE-15m-Telephone-Extension-Kit-2-3a-Socket-Tool-Instructions-/191751175319? Let's hope those instructions are idiot proof :)
  14. M

    Extending BT socket

    Awesome, thanks for responses all. So I just need some cable (will cat 6 work?), a slave socket and a krone tool? Anyone with a link to a decent wiring diagram would be useful. I've looked at many but cannot determine which is the best/definitely correct for my purposes :)
  15. M

    Extending BT socket

    I have read about this at length and am still none the wiser, so apologies if repeating myself... I am renovating a flat and would like to move the router to a central position (at 8m down the corridor) to get better coverage. I'd like to co-ordinate so that it happens when everything is upside...
Back
Top