It's neither of them Jeff
There's a leak somewhere
Flue not sealed
Hob not right
No sleeving on gas pipe
Ill price to fix that lot but can't go ripping floors up I suppose !
Would you report this lot or just crack on and charge accordingly ?
Gas meter was capped by NG - apparently swapped a pre pay for normal meter
took cap out and put test on. 10mb down to 0mb in 20 seconds. Put cap back in
The house has been done up quite nicely but what is this lot? tenant due to move in thursday. No books or fook all in sight, has the...
heat only boiler
6 radiators
cylinder
3 port valve
call for heating and hot water - water only warm and downstairs rads cold at the bottom
put hot water on its own - red hot
put heating on its own - red hot
love this post :D
mbga9pgf hahahahahhaha
im HETAS and Gas Safe, i just fire the stoves in, dont give certificates or alarms or anything.
i even fitted a stove upside down yesterday as thats what the customer wanted so i just did it, bugger the regs as long as customer happy and paid...
If your radiators are sludged up, (bottom middle of rads are cold) you will need it powerflushed and dislodging
merely draining down and re fillling will not get rid of the sludge
if your system was powerflushed and treated correctly you shouldnt have any problem, unfortunately a high...
think its 3 bar will have to double check or i could be making that up. what if i took the vented tap off put normal one on and put the pressure reducing valve to 1 bar with a PRV set to 2.5 bar?