Recent content by Miksu

  1. M

    Honeywell GD link-problems

    It's been set to reflex and it seems to be working now! I can turn my lights on using MQTT Explorer :mrgreen: Programming links outdoors using keypad is PITA, we have now snow here :eek: One zone gives me still DR. MASKED, but it's probably something wrong with link configuration, summary in...
  2. M

    Honeywell GD link-problems

    Hi, I'm having troubles programming links. I have succesfully set up SelfMon virtual, it can read and write zones using MQTT commands. I have created link from virtual zone to onboard output, for some reason, linking doesn't seem to work. I just want output 1012 to follow zone 1052. When 1052...
  3. M

    Galaxy Dimension links and spare zones

    Have been studying GD installation manual intensively and installed three systems, but I haven't exactly found out, is it possible to use spare zone as link source, since panel monitors them anyway? My intention is to use (spare) zone (onboard GD48) for movement detector (with twilight sensor)...
  4. M

    Alpha vs V2GY

    Alpha is newer protocol and it gives longer lifetime for sensor batteries, usually battery lifetimes given by Honeywell are like three years on V2GY and four years on Alpha. Alpha is obviously more energy efficient, probably it's more resistant for interference. Alpha protocol sensor can send...
  5. M

    Honeywell TouchCenter communication issues and lightning control

    Did recently some tidying on my Dimension connectors, attached are "before" and "after" pictures, I guess it's easy to see which one is before and which one after. Replacing Krone-row connector and other shady components improved reliability even more, comms quality on TC+ is constantly around...
  6. M

    Honeywell TouchCenter communication issues and lightning control

    This looks interesting, especially possibility to use MQTT. I have surveillance camera system (BlueIris in Windows PC and 4 IP FHD-cameras) that supports MQTT. MQTT-control would make it possible to turn on lights when motion is detected by cameras, start recording on all cameras on burglar...
  7. M

    Honeywell TouchCenter communication issues and lightning control

    Got this sorted out, I guess, or at least it's been working for about week without issues. Resistance was around nominal 680 Ohm. Thing that seemed to help was using separate power supply for TC+ and Mk8 keypad. They are supplied now by same PSU as my fire alarms. TC+ gives still low...
  8. M

    Honeywell TouchCenter communication issues and lightning control

    Hi, I'm having frequent (couple times a day) keyboard lost-problem with TouchCenter Plus connected to GD-48 (firmware 7.something). Keyboard diagnostics give connection quality varying between 0% and 100%. Cabling is Cat5 unshielded/ Cat6 shielded, last part to mk8 keyboard is 2-pair shielded...