Update !!
New thermostat fuse fitted and all back up and running (y) I even managed to return the heater element I didn't need for a full refund.
Mega thanks to jj4091for advice and diagnosis methods. It just goes to prove that with a little bit of determination, the ability to use a...
Thank you very much for your prompt and very good advice. I managed to conduct your suggested tests without electrocuting myself :sneaky:
No power recorded through the plug and socket connection. Took the front off the machine and found the thermostat fuse, and as you guessed no continuity...
I have a Hoover Vision Tech VTV581NC tumble dryer which although still tumbles all the panel lights are flashing as well as a beeping sound and no heat. I did a little bit of online research and most suggestions pointed towards the heating element. I have just changed for a genuine hoover...
Thank you very much, I will do that as the thermostat is located about 2 feet away from programmer so should be easy to do a continuity check on each wire.
Thanks all for previous advice and suggestions very helpful (y)
Sorry I have not been back to you sooner. I now have time to experiment again. Forgive me if im being thick but are you suggesting I should not connect the wire I have labelled 4 but instead connect to terminal 4 the red wire that was in the connector block with the yellow?
The other wires...
The cables were all marked by me so I could try and get my head round what went where by tracing them to where they are connected in the wiring centre. I marked that cable as rm stat because the red wire and earth wire went to rm stat in wiring centre, there is a third wire in that cable which...
Thanks Ian I think you are right and I have actually taken the easy route by placing the red and yellow in a common terminal and the hive is working as it should.
The wiring is a bit of a mystery as to what goes where so unless someone else comes up with a definitive answer for removing the stat...
Hello good people I hope you can steer me to what I should do to achieve the above. My system is a Y plan with my boiler, hotwater tank, water supply tank, 3 port valve and wiring centre all located in my attic. I have installed hive and all appears to be working fine by connecting the live...