Recent content by monkplumber

  1. M

    injector tee and bad flow to cylinder

    yeah not sure what my local heatmerchants stocks but sure ill see what they have
  2. M

    injector tee and bad flow to cylinder

    yeah the boiler is cross flowed, there is only 2 connections on the stanley lismore unlike most of their other stoves which normally have 4 connections
  3. M

    injector tee and bad flow to cylinder

    well i,ve finally think i,ve solved my injector tee problem,i had the pump turned down to its lowest speed setting,i,ve since turned it up to the middle speed and the gravity circuit seems to be working now when the pump is on, the higher velocity of the water coming through the venturi must be...
  4. M

    injector tee and bad flow to cylinder

    so would the stat on the return turn on the pump and then the stat on the flow turn it off,eg,return reaches 60 and pump comes on and flow reaches 40 and pump turns off.would you just use 2 ordinary pipe stats and if so how would you wire it. when the pump operates is it not the job of the...
  5. M

    buffer tank sizing

    i am currently building my house and i wanna install a buffer tank.i am gonna heat the buffer using a condensing boiler but i will mainly use a stanley solid fuel stove to heat the buffer. the buffer is gonna suppply 15 rads and also a 300l hot water cylinder,i was wondering what size buffer...
Back