Recent content by mooney3

  1. M

    HIB Cyclone Bathroom inline extractor

    Hi, I have a HIB Cyclone Inline extractor that was fit in my bathroom just over a year ago. Over the weekend I went in the attic to get suitcases out and noticed the flexible outlet pipe had come off the extractor outlet connection point. I put it back on and tightened up the clamp. Today I...
  2. M

    Side entry 1/2 inch toilet cistern

    Hi, I have a new inset toilet cistern that has a 1/2 inch side entry plastic male connector. When I screw the plastic cistern into the middle of the unit there isn't much space left for a flexible 1/2 inch to 15mm to screw onto the plastic pipe without kinking the flexi pipe. The 15mm end of...
  3. M

    Reginox Virage pull out Tap seems blocked

    Photo with cold water coming out, another with hot water coming out and a third photo just of the tap. Excuse the cloth and elastic bands, they are just to stop the flexi pipe retracting back into the housing. The lever isn't even at half pressure as the water would be all over.
  4. M

    Reginox Virage pull out Tap seems blocked

    Hi, I can get a needle into the aerator and it turns easily, there is a turbine within the faucet that when it turns gives off a colour dependant on the temp of the water, this also turns easily. Other than that the faucet looks like a sealed unit that I can't get in to, as you can see in the...
  5. M

    Reginox Virage pull out Tap seems blocked

    Hi, I fit a new Reginox Virage pull out tap to my kitchen sink in August 2019 (4 months old). I have had no problems until tonight I have gone to pull the lever to get water out and neither cold or hot water will come out. I have removed the spray faucet and there is lots of water pressure on...
  6. M

    6mm swa to 10mm t&e

    Of course, just trying to reduce the cost and putting my inexperienced 3 years of college work in to practice. I appreciate the testing that has to be carried out at the end. Thanks
  7. M

    6mm swa to 10mm t&e

    Hello PrenticeoyofDerry. The 50A breaker is protected by a 63A RCD as it is an IP65 shower kit enclosure.
  8. M

    6mm swa to 10mm t&e

    Hi, I am having a hot tub delivered and I want to make a connection in the loft between 6mm swa and 10mm t&e, I intend to run the cables along the rafters so no insulation involved. The reason for the 10mm t&e is that I had an extension built and had a 50amp breaker installed next to the...
  9. M

    IGNIS ADL 347 dishwasher problem

    Hello, my dishwasher has developed a problem where it stops during its cycle and beeps continuously. The start light doesn't have a pattern and flashes constantly with no pauses. The dishwasher can stop at any time during the cycle, after 10 mins, 20 mins, 30 mins etc, there is no...
  10. M

    Isar HE30 & Honeywell CM907 electrical connections

    Hello Mikely, boiler now up and running with programmer. Thanks Paul
  11. M

    ISAR HE30 & Honeywell CM907 Electrical connections

    Thank you for your assistance. Boiler now up and working with the programmer. In answer to your last question. The wireless system started to act up. Changed all the batteries, reset the RF, binded the thermostat and receiver, put the thermostat directly in front of the receiver, but still...
  12. M

    Isar HE30 & Honeywell CM907 electrical connections

    Sorry Mikely, sausage finger typo error. It is in fact a CM61NG programmable thermostat and not the CM31. I will try as you suggest but does that mean I blank off the Black wire with a connector box ? Regards Paul
  13. M

    ISAR HE30 & Honeywell CM907 Electrical connections

    Hi, if you can see the 2 pictures, on the first picture with the 2 back boxes you can see a 3 core and earth white sheather cable coming upwards through the middle of the 2 back boxes. This is the cable coming from the boiler. The black and the brown go to the 2 load connections on the...
  14. M

    Isar HE30 & Honeywell CM907 electrical connections

    Hello, advice needed. I am replacing my Honeywell HC60NG & CM31NG with a Honeywell CM907 but I need some assistance with the electrical connections. In situ at the moment is a 3A fused switch (See photo) to which the Earth brown and black from the Isar HE30 are connected. The Grey is...
  15. M

    ISAR HE30 & Honeywell CM907 Electrical connections

    Hello, advice needed. I am replacing my Honeywell HC60NG & CM61NG with a Honeywell CM907 but I need some assistance with the electrical connections. In situ at the moment is a 3A fused switch (See photo) to which the Earth brown and black from the Isar HE30 are connected. The Grey is...
Back
Top