Could there be anything else causing such a big drop in the pressure (from 19mbar - 15mbar) because that seems pretty large a drop if to get the required pressure it is only allowed to drop 1mbar?
Would replacing half of the piping with 28mm be sufficient?
plus I have seen people saying that at the gas meter it should be 21mbar.
Is this correct? If i got the gas board to sort that out would that make it 17mbar at the boiler and less of a problem?
The only gas appliance in the house is the boiler (there is a T joint going off with 15mm that supplied the old boiler but that has been blanked off). Yeah I THINK he had pressed the boost button on the boiler to have it going at full whack when he tested the pressure at the boiler, he...
Hi I had a new Worcester greenstar 37CDi fitted 20 months ago. At the time the fitter said he had to fit a new larger gas supply pipe annd fitted a 22mm pipe.
I had a friend of the family (works for one of the big companies servicing boilers) service the boiler today as we had been having...