    Central heating only luke warm

    @transam - Hot water is fine, can even adjust it to 'scolding' level. @fixitflav - It's a new problem. I've only been in the property for around a year and do remember it working well initially when I first moved in. Boiler hasn't been changed since build (as I have the original paperwork and...
  2. N

    Central heating only luke warm

    Hi experts, I have a Ideal Logic Combi ESP1 35 boiler and its c.6 years old in my 'new' build. I also have a two wired Danfoss TP5000si thermostats, one upstairs and one downstairs connected to two Danfoss HPA2 2-port actuators, as you'd expect. Problem I have is that neither of the thermostats...
  3. N

    Salus RXVBC605 installation in Vaillant ecoTec + 937 boiler

    I've bought myself a Salus it500 wireless thermostat with wi-fi connection - which is all working and connected to my iPhone. Whilst I await for delivery of the Salus RXVBC605 receiver which is designed to slot into the front of my boiler, I opened up the boiler and the electronics control...
  4. N

    Strange boiler behaviour...help required !!

    ...after a further look, I see that the pressure gauge is reading very low, way below the red pointer and the temperature gauge isn't working at all. I'll call in the experts and take it from there. Thanks for the help !
  5. N

    Strange boiler behaviour...help required !!

    I'll check the wiring tonight (I have the original booklets) and see what is correct and what isn't. Will also open bathroom/kitchen taps and report back.
  6. N

    Strange boiler behaviour...help required !!

    Thanks for the info but no aerator on this box standard kitchen tap. Could the boiler trip out even when the tap is opened fully ? I'll report the flow rate of the hot water tap in full flow but it looks as though the water flows much quicker in the kitchen than it does in the bathroom.
  7. N

    Strange boiler behaviour...help required !!

    Hello, I have just moved into a house where we have a Vaillant VCW GB 280 H Combi-boiler fitted. This is my first experience of an 'older' combi-boiler but we have strange going-ons here...let me explain.... 1. We have a Potterton programmer which has a timer for CH and HW - being a combi...
  8. N

    Radiators are hot when only hot water is required

    No probs. Will try them directly. Thanks.
  9. N

    Radiators are hot when only hot water is required

    Gents, (& Ladies if any), I unscrewed the electronics from the valve and I saw a rotary semi-circular shaft on the valve itself. This I was able to rotate with little resistance. The electronics box contained a female insert where I assume the shaft locates into. When the system was...
  10. N

    Radiators are hot when only hot water is required

    Sorry for the delay !! The motorised valve is A Potterton MSV322 which has LED's for Central Heating and Domestic Hot Water. When the appropriate function is selected then the LED's correspond as expected, i.e. When Hot Water is selected on the controller, the Domestic Hot Water LED is...
  11. N

    Radiators are hot when only hot water is required

    Hello, I have a conventional boiler system (immersion tank but no combi) and I have noticed recently that when I select 'WATER ONLY' on my controller, all my radiators become hot ! Its becoming a little unbearable in this hot weather. Anyone any idea's and any advice on what I can do...