Recent content by Pee Jay

  1. P

    Honeywell Galaxy G2-20 Key Fobs

    Finally got the keyfobs working today. I always suspected that the RF portal was faulty so, I bought a replacement, and once fitted the keyfobs worked! I didn't have to make any changes to the system setup. Many thanks for your assistance. I had requested support and later a replacement card...
  2. P

    Honeywell Galaxy G2-20 Key Fobs

    No I don't have any means of dumping the panel settings. I did look for information regarding connecting the programming port, on the alarm panel, to a PC's serial port, but no luck. When the key fobs operate correctly, what indication is there on the fob and on the rf portal's RX and TX...
  3. P

    Honeywell Galaxy G2-20 Key Fobs

    On the portal there are the following labels: - F135 00 300 VI DataCode 1504 ICT P12B073 FCT 1401033 So I guess, from the F135 label, the firmware is version 3.
  4. P

    Honeywell Galaxy G2-20 Key Fobs

    I removed and replaced the battery in both of my key fobs, holding the unset and full set buttons (to change to Alpha mode) Both key fob user serial numbers were cleared so I went through the learn process which restored the serial numbers. There was an alert, 'RF Jam Recv. 5'. Pressing the...
  5. P

    Honeywell Galaxy G2-20 Key Fobs

    Yes, 51.50.1=RF Fob unset, is set to 1=Unset anytime The keypad firmware is: Galaxy 2-20 V1.56 The RF portal firmware is: 100-05121 REV.A2 On the RF portal, the links are set: - 1 closed (a1 + V2) 2 open (-) 3 closed (Ant1) 4 closed (Galaxy) 5 open (-) 6 open (-) LK1 open LK3 open
  6. P

    Honeywell Galaxy G2-20 Key Fobs

    The system does set ok, using the keypad. I'll let you know the firmware versions tomorrow (the system was bought in August this year). Thanks for your help with this.
  7. P

    Honeywell Galaxy G2-20 Key Fobs

    The two key fobs have been 'learned' and returned their serial numbers (0993919 and 0732958). Also both key fob users have been allocated pin numbers and set to L2.
  8. P

    Honeywell Galaxy G2-20 Key Fobs

    I've just installed a Honeywell Galaxy G2-20 along with the RF portal (no wireless sensors) and have two TCC8M key fobs. The system is fully working except I'm unable to set or unset the alarm using the key fobs. The system is configured as follows: - RF Portal address 5 Keypad address 0 Two...
Back