Recent content by petenjr

  1. P

    Desolder with water in pipes, can it be done?

    The easy way to make sure you dont end up with this sort of problem again is to use push on plastic stop ends they work in seconds i have even been known to cut live pipes and slam a push fit stop end on if the stop cock is naff or like the last one i had where the stop cock could not be found !
  2. P

    Worcester Bosch 280 problems

    Yes Pump I'll have to give that a prod tomorrow see if it is the guilty party could well be part of it but would it kettle so quickly if it was the pump still need the PV and PRV changing almost a case of is it worth it or is it better to replace the boiler completely Pete .
  3. P

    Worcester Bosch 280 problems

    Hi . My brothers having problems with his boiler in as much as it keeps venting now i know the PRV needs changing but i also suspect the Pressure vessel is shot i take it there should not be water at the schrader valve on the vessel this happened 2 days ago it now kettles almost instantly on...
  4. P

    Heatline Star 24 combi boiler problem no hw or ch

    Hi contray to the above i have had to replace Both relays on the PCB on my bolier they are way under sized for the job they are doing fortunatley the board will take a larger and somewhat more capable device this solved my problem it has been ok ever since